9763 MCI Pre-installation information
Verify site preparation
The following site preparation requirements should be checked and met before the
installation of the equipment can begin. If some of the requirements are not met, the
installer must do so now:
• Ensure equipment is planned to be installed as high as possible to avoid obstructions
• Consider nearby sources of interference. Also check possibility of future obstructions.
• Ensure adequate clearance is provided for service access
• Ground, power and backhaul cabling has been routed and is in place
• Ensure any site specific fixing materials (screws, washers, wall plugs) for pole/wall
mounting the equipment are available.
Product delivery contents
Unpack and examine the product packaging contents. If you notice any damage, or
missing items as listed in the Packing List, immediately notify the carrier that delivered
the unit and contact your Alcatel-Lucent representative.
The product packaging contains the following items:
• The Alcatel-Lucent 9763 Metro Cell Indoor V1.0 B25 LTE 2x250mW.
Installation materials
In addition to the standard product deliverable ensure the appropriate mounting brackets,
installation kits and ancillary items are available to support the product mounting options.
Figure 3-1 9763 MCI mounting bracket
9763 MCI installation
9763 MCI pre-installation
9763 MCI Pre-installation information
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9763 MCI
3MN-MCI-IMOP
Issue 1
December 2013
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
3-3