The following figure shows a typical indoor AISG configuration using a home run
solution:
Note: If applicable, outdoor AISG cable runs must be grounded at the facilities
bulkhead and every 60 m (200 ft).
Remote antennas
Cable shield
grounded at
bulkhead entrance
Cable shield
grounded at 60 m
intervals
Cable shield
grounded at
bulkhead entrance
Cable shield
grounded at 60 m
intervals
Surge Prot
IN
OUT
Surge Prot
IN
OUT
Surge Prot
OUT
IN
RRH indoor
AISG home run configuration
AISG
Antenna_1
RCU
IN
OUT
Facilities bulkhead
Cable shield
grounded at
bulkhead entrance
Cable shield
grounded at 60 m
intervals
RRH
TX1/RX1
TX2/RX2
ALD (AISG)
RRH1_TX1/RX1
RRH1_TX2/RX2
AISG
AISG interface
AISG cable requirements
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
9-6
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
B25 RRH4x30
3MN-02023-0001-RJZZA
Issue 0.02
January 2015