E F Johnson Company 2422001-1 Benutzerhandbuch

Seite von 198
ALIGNMENT AND TEST PROCEDURES
7-6
August 2000
Part No. 001-2001-200
9. Press the space bar to key the Exciter.
10.Set RV101 for "best" square wave as observed on 
the modulation analyzer output to the oscilloscope.
NOTE: Ensure that the oscilloscope is "DC" coupled 
and turn off de-emphasis and HPF switches on the 
Modulation Analyzer.
11. Press the space bar to unkey the Exciter.
12.Repeat Steps 1-7. Very little adjustment of RV401 
should be needed.
7.3 110W POWER AMPLIFIER ALIGNMENT
7.3.1  INTRODUCTION
Refer to Figures 7-3 and 7-4 for component loca-
tions.  Refer to Figure 7-8 for equipment needed and 
setup diagram.  Select "PA" from the "TEST" menu in 
the Repeater Software.
7.3.2  DRIVER TUNING AND LIMIT ADJUST-
MENTS
1. Connect an antenna or dummy load to the RF port 
(50 ohm impedance).
2. Connect the:
Power supply ground lead to P105
+15V DC lead to P103
+26.5V DC lead to P101
36-pin cable to J101 on the RFIB
3. Set the signal generator to +19 dBm 
±
0.1 dB.  
Connect the signal generator to A9.
4. Press the space bar to key the PA.
5. Monitor the voltage on R45 on the RFIB and set 
R76 for 1.3V DC (see Figure 7-4).
7.3.3  POWER AMPLIFIER TUNING
This procedure assumes that either:
The carrier is chosen and the coaxial cable from the 
exciter is putting out +19 dBm
OR
A test signal is being injected to the PA with 
+19 dBm.
Connect an antenna or dummy load to the RF 
port (50 ohm impedance).  Use the carrier frequency 
needed.
1. Set RV501 on the PA fully counterclockwise. 
Set RV502 on the PA fully clockwise, see 
Figure 7-3.
2. Set Forward Power Adjust RV601 and Reflected 
Power Adjust RV602 on the power detector board 
fully counterclockwise (see Figure 7-3).
3. Monitor the voltage on R45 on the RFIB and set 
R76 for 1.3V DC (see Figure 7-4).  This sets the cur-
rent limit point for driver Q501 at hot temperatures.
4. Set each of the quiescent currents for Q502 and 
Q503 for 10 mA (DC) each.
5. Program the power output for the correct frequency 
range as follows:
132-150 MHz  110W
150-178 MHz  110W
6. Press the space bar to key the PA.  Output power 
will be approximetly 80W.
7. Monitor the output power and tune C601 and C602 
for maximum output power (see Figure 7-3).
8. Set Forward Power Adjust RV601 for rated power 
(110W or 100W).
9. Press the space bar to unkey the PA.
10.Disconnect the antenna or dummy load from the RF 
port.
11. Press the space bar to key the PA.
NOTE: This will not harm the PA.
12.Adjust Reverse Power Calibration Pot RV602 for 
equal voltages on W121 and W126 on the RFIB or 
for equal Forward and Reverse Power
(see Figure 7-4).
13.Press the space bar to unkey the PA.