E F Johnson Company 2422001-1 Benutzerhandbuch

Seite von 198
ALIGNMENT AND TEST PROCEDURES
7-12
August 2000
Part No. 001-2001-200
Receiver Audio Distortion Measurement
1. Adjust the RF generator for 100 
µ
V into the 
Receiver with a modulation tone of 1 kHz at 
±
3 kHz deviation (25 kHz channels) 
(±1.5 kHz deviation 12.5 kHz channels).
2. On the MAC, insert test cables into J100/J103 and 
connect to an AC voltmeter.
3. Adjust R237 for 0 dBm (775 mV RMS).
4. On the MAC, connect a 16 ohm load and distortion 
analyzer to J101 or J104.
5. Adjust R236 for 2.8V RMS and measure the distor-
tion.  Distortion should be < 3%.
Receiver Hum and Noise Measurement
1. Adjust the RF generator for 100 
µ
V into the 
Receiver with a modulation tone of 1 kHz at 
±
3 kHz deviation, 25 kHz channels 
(±1.5 kHz deviation 12.5 kHz channels).
2. On the MAC, connect a 16 ohm load and distortion 
analyzer to J101 or J104.
3. Adjust R236 for 2.8V RMS.
4. Remove modulation from the RF generator.  The 
measured level must be 
 -50 dB.
Receiver SINAD Measurement
1. Adjust the RF generator for 100 
µ
V into the 
receiver with a 1 kHz tone at 
±
3 kHz deviation 
25 kHz channels (±1.5 kHz 12.5 kHz channels).
2. On the MAC, connect a 16 ohm load and distortion 
analyzer to J101 or J104.
3. Adjust R236 for 2.8V RMS.
4. Re-adjust RF level for 12 dB SINAD.
12 dB SINAD reading should be 
 0.35 
µ
V.
Receiver Squelch Adjustment
1. Adjust the RF generator for 100 
µ
V into the 
receiver with a 1 kHz tone at 
±
3 kHz, 25 kHz chan-
nels (±1.5 kHz deviation 12.5 kHz channels).
2. On the MAC, connect a 16 ohm load and distortion 
analyzer to J101 or J104.
3. Adjust R236 for 2.8V RMS.
4. Set the RF generator output for 5 dB SINAD.
5. On the MAC, adjust R234 so the Receiver just 
squelches.
6. Increase the RF generator output until the Receiver 
unsquelches.  Reading should be 
 10 dB SINAD.
Receiver Data Level Adjustment
1. Adjust the RF generator for 100 
µ
V into the 
receiver with a 100 Hz tone at 
±
1 kHz, 25 kHz chan-
nels (±800 Hz deviation (12.5 kHz channels).
2. On the MAC, insert test cables into J100/J103 and 
connect to an AC voltmeter.
3. Adjust R235 to achieve 340 mV RMS.
Local Speaker/Microphone Check
1. Adjust the RF generator for 100 
µ
V into the 
receiver with a 1 kHz tone at 
±
3 kHz deviation, 
25 kHz channels (±1.5 kHz (12.5 kHz channels).
2. On the MAC, plug a Speaker/Microphone into 
J101/J102.
3. Adjust R236 until the 1 kHz tone is heard.
Receiver Desense Check
1. Adjust the RF generator for 100 
µ
V into the 
receiver with a 1 kHz tone at 
±
3 kHz deviation, 
25 kHz channels (±1.5 kHz 12.5 kHz channels).
2. On the MAC, connect a 16 ohm load and distortion 
analyzer to J101 or J104.