4.5 HARDWARE
Figure 4-19   HARDWARE MENU
4.5.1  HSDB MONITOR
High Speed Data Bus (HSDB) connects all 
repeaters at a site and continually sends updates on the 
status of each repeater.  This information screen pro-
vides a list of all repeaters at the site (1 to 20).    If a 
repeater is not sending data, IDLE is next to the 
repeater number.  The data sent by the repeater is used 
to determine the Home, GID and UID of destination 
(mobile) users to receive the call placed by the 
originator.
The Home column refers to the Home repeater 
number of the originator, therefore the Repeater num-
ber and the Home number may not be the same num-
ber.  The UID is the Unique ID used to identify the 
originator of special calls.   The GID column refers to 
the Group ID of the talk group of the originator 
(236=UID Call, 237 Telco call).  The GoTo column 
shows the repeater channel all destination users switch 
to so they receive the call. 
Figure 4-20   HSDB MONITOR
4.5.2  RECEIVE/TRANSMIT DATA
This is an information screen used at the repeater 
site while the computer (laptop) is connected to the 
MPC in the repeater being monitored.  This informa-
tion is contained in the receive data stream exchanged 
between the repeater and the destination user (mobile) 
and the data content of the repeater transmit data 
stream.  The message contains data received from the 
destination and data sent to the mobile by the repeater.  
The repeater receives the destination’s: Unique 
ID, Home Repeater Number, Group ID, Priority, Sta-
tus and Time Stamp.  The information sent to the des-
tination in the update message from the repeater 
includes: Unique ID of originator, Home Repeater 
Number, Group ID, GoTo Channel Number, Free 
Channel Number and Priority of the current repeater.  
The time stamp is included because messages are sent 
continually and this provides a reference for when a 
data exchange took place.
Figure 4-21   MOBILE TRAFFIC MONITOR
4.5.3  RF DATA
The A/D Monitor Screen shows the state of the 
lines (see Figure 4-22).  These lines are monitored by 
the A to D converter in the IAC.  The normal values 
for each line are defined as follows.
Synthesizer Lock Lines
Yes or No
Forward Power (LP)
25-110 Watts
Reflected Power
0-6 Watts
Final Out (ratio)
approx equal
Chassis Temp
27
°
C-55
°
C
Wideband Audio Output
approx 200
LO Injection
approx 200
RSSI
20-150
Fan Current
100-200, 0
Fan
On or Off
Power Supply Temp
22
°
C-45
°
C
Battery Voltage
21V-28V
Values with no label are the actual A to D read-
ing.  To calculate the voltage on the line, divide the 
value by 51.  Example: Value
 ÷
 51 = Volts.  Any varia-
tion from the above values may indicate a problem in 
that area.  Values on this screen are relative measure-
ments only.