RADIO-WIDE FEATURES
15
May 2002
Part No. 002-5100-100
Selecting a Scan List
Conventional Operation - The scan list is user select-
able if the Scan (List) Select option key or menu 
parameter is programmed. Otherwise, it is a fixed list. 
Changing a list with this option key or menu param-
eter is temporary since the programmed default list is 
reselected at power up. 
SMARTNET/SmartZone Operation - Each channel 
(talk group) is programmed to select one of 
programmed lists. In addition, each channel can be 
programmed so that scanning is automatically enabled 
or disabled (No List) when it is selected. If the Scan 
(List) Select option key or menu parameter is 
programmed, the list that is selected by all channels of 
the current system can be temporarily changed. The 
default list programmed for each channel is automati-
cally reselected at power up. 
Select the scan list as follows:
1. With scanning disabled (
 icon not displayed), 
press the Scan List option key or select the Scan 
Selct menu parameter.
2. The currently selected list is displayed as “List x”, 
where “x” is the currently selected list. To exit 
without changing the selected list, simply press the 
Scan List option key again or the F1 or F2 key.
3. To select another list, press the Up/Down switch. 
When the desired list is displayed, select it and exit 
this mode by pressing the Scan List option key again 
or the F2 key.
Programming a Scan List
If the Scan Edit option key or menu parameter is 
programmed, conventional and SMARTNET/
SmartZone standard scan lists can be programmed as 
follows. Changes are permanent (cycling power does 
not reselect a default condition). 
1. Make sure that both standard and radio wide scan-
ning are off (
 icon not displayed). Select a 
conventional or SMARTNET/SmartZone channel 
corresponding to the scan list being programmed.
2. Select the scan edit mode using the Scan Edit option 
key or menu parameter. This mode is indicated by 
 in the display. 
3. If applicable, select the list to be edited by pressing 
the Up/Down switch. Select the desired list by 
pressing the F2 key. The selected list is indicated as 
“LIST x”. If user programming is disabled on a list, 
“NO EDIT” is momentarily displayed and it cannot 
be edited.
4. Select the channel you want to add or delete by 
pressing the Up/Down switch. After the last channel 
in the current zone is displayed, the first valid 
channel in the next zone is displayed and vice versa. 
Lists are limited to 16 channels. If an attempt is 
made to add more than 16, “LIST FULL” is 
displayed and a channel must be deleted before 
another can be added. 
NOTE: A conventional priority channel cannot be 
deleted (see page 18)
.
5. If the selected channel is in the scan list (scanned), 
the 
 icon is displayed. To change the status of 
the displayed channel, press the F2 (Enter) key. 
With conventional channels only, if the selected 
scan list is programmed with a fixed priority 
channel (see page 18), the next press of F2 makes 
the current channel the priority channel. The 
 
icon is then displayed to indicate that it is the 
priority channel. 
6. To exit this mode and save the changes, press the F1 