E F Johnson Company 2425180 Benutzerhandbuch

Seite von 62
TRANSCEIVER PROGRAMMING
3-13
September 2001
Part No. 001-5100-001
Timers
Tx Time-Out Timer - This timer limits the length of 
transmissions (Section 2.4.10). Times up to 3 min-
utes, 45 seconds in 15-second steps can be 
programmed.
Penalty Timer - This timer disables transmitting after 
the time-out timer expires (Section 2.6.7). Times up 
to 3 minutes, 45 seconds in 15-second steps can be 
programmed.
Conversation Timer - This timer limits the total 
length of a conversation (Section 2.6.8). Times up to 
7.5 minutes in 0.5-minute steps can be programmed.
Busy Channel Override - Selects if the Busy Channel 
Lockout feature can be overridden by quickly releas-
ing and then pressing the PTT switch (Section 2.6.5).
 Scan List Screen
Clicking the Scan List in the left pane or that 
button in the General screen displays the following 
screen which is used to program the conventional scan 
lists described in Section 2.5.5. 
NOTE: The conventional scan lists cannot be 
programmed until all the conventional channels are 
programmed. Therefore, first program the channels as 
described in Sections 3.5.5, 3.5.6, and 3.5.7.
Conventional System Scan List Screen
To modify a list, click 
 and the 
screen which follows is displayed. Select the desired 
scan list in the box on the top and then select the zone 
and the channels from that zone to be included. Repeat 
for each zone. Do this for each list programmed. The 
 button deletes the selected channel(s) 
from the scan list.
Conventional System Modify Scan List Screen
The following parameters are programmed in the 
preceding Conventional System Scan List Screen.
Keypad Editing
This selects if the user is allowed to edit the scan 
list. This requires the Scan Edit option switch as 
described in Section 2.6.12. User editing can be 
enabled or disabled on each scan list.
Scan Mode
This function selects the channel on which trans-
missions occur when the PTT switch is pressed while 
scanning. In addition, it selects if priority sampling is 
used and also the type of priority channel (see 
“Priority Channel” description which follows). The 