6-11
SmartNet / SmartZone / P25 Trunked Features
To change the current status, press the Up/Down buttons until the desired status is 
displayed. Then to send the status, press the <F2> (Select) button or momentarily press 
the PTT switch. One of the following events then occurs:
- If five beeps sound and “Ack Rcvd” is displayed, the status was received and 
acknowledged by the system.
- If after five tries the message is not acknowledged, a tone sounds and “No Ack” is 
displayed.
Note
Only the status number assigned to the alias is sent – not the actual text of the status 
condition alias itself.
6.8
Emergency Alarm and Call
Emergency Alarms and Calls are separate functions that can be individually enabled or 
disabled on each SmartNet/SmartZone and P25 Trunked system. The Emergency option 
button (or menu parameter) is required for these functions. Other emergency features are 
as follows:
• Emergency Alarms are transmitted on the selected talkgroup if emergency calls are 
disabled, and on the emergency talkgroup if emergency calls are enabled.
• Emergency Call talkgroup selection priority is as follows. For example, if a global 
emergency channel is not programmed, the emergency talkgroup of the selected 
channel is used and so on.
a
Global (radio wide) emergency channel
b
Emergency group of the selected channel
c
Talkgroup of the selected channel
d
Announcement group of the selected channel
Up to 255 Emergency Lists may be programmed. A specific list may be selected for each 
channel.
6.8.1 Emergency Alarms
An emergency alarm is a special transmission that alerts a dispatcher of an emergency 
situation. It is sent automatically by simply pressing the Emergency option button or 
selecting the Emergency menu parameter. The system to which the emergency channel is 
linked must have Emergency Alarms enabled. If not, Emergency Alarms are disabled. The 
alarm is sent on the control channel.
Preliminary Draft 3/9/12