SMARTNET / SmartZone / P25 Trunked Features
7.2.1
Radio Info Button
Pressing the Radio Info button (if programmed) or selection of the menu parameter allows 
the user to display the ID programmed for the currently selected protocol. If the radio is on 
a digital conventional channel, it shows the digital conventional ID. If the radio is 
currently on a SmartNet/SmartZone or P25 Trunking channel location, it shows the ID 
associated with that protocol. This feature also shows the following items:
• Band
• SEM
• File Format
• ESN
• Bootload Version
• DSP
• IP  Address
• Encryption Key location programmed for the currently selected channel
• Unit ID for active protocol
• Radio Equipment Identification number
• Memory  Used
• Current Software version in the radio
7.3
Standard Group Calls
Standard calls are between you and another mobile, group of mobiles, or a control station 
(a radio in a fixed location). Most calls are probably this type. Proceed as follows to place 
and receive group calls.
7.3.1
Placing a Standard Group Call
To place a Standard Group Call:
Turn power ON and set the volume as described in Section 4. Select the channel 
programmed for the talkgroup you want to call (see Section 4.1.6.3).
If the talkgroup is programmed for encryption and is not strapped to Clear or Coded, 
select the desired mode by pressing the C/S (Clear/Secure) option switch or selecting 
the menu parameter. The status of that switch is ignored if the talkgroup is strapped to 
Clear or Coded. Refer to Section 8.3 for more information.
Press the PTT switch and begin talking. An optional talk permit tone may sound to 
indicate when talking can begin. Other indications that may occur are as follows: