E F Johnson Company 2425M80 Benutzerhandbuch

Seite von 207
Draft 02 - Sep 1 2015
5-32
Conventional Mode Features
SCAN TIMER - Selects the Scan Hold timer. Rotate the Select switch to decrement/
increment the timer in 0.5-second steps from 0-7.5 or set it to 0 seconds to disabled it. 
When the desired value is displayed, store it by pressing the Select switch. A single 
beep sounds when the switch is pressed (if that option is enabled). 
TX TIMER - Selects the transmit time-out timer. Rotate the Select switch to 
decrement/increment the timer in 15-second steps from 0-225 or disable it by selecting 
0 seconds. When the desired value is displayed, store it by pressing the Select switch. A 
single beep sounds when the switch is pressed (if that option is enabled). 
PEN TIMER (SCH)/Penalty Time (LCH) - Selects the penalty timer. Rotate the 
Select switch to decrement/increment the timer in 15-second steps from 0-225 or 
disable it by selecting 0 seconds. When the desired value is displayed, store it by 
pressing the Select switch. A single beep sounds when the switch is pressed (if that 
option is enabled). 
CONV TIMER (SCH)/Conversatn Timer (LCH) - Selects the conversation timer. 
Rotate the Select switch to decrement/increment the timer in 30-second steps from 0-
450 or disable it by selecting 0 seconds. When the desired value is displayed, store it by 
pressing the Select switch. A single beep sounds when the switch is pressed (if that 
option is enabled). 
5.14.6 Channel Parameters
The “CHAN PARMS” (Standard Control Head) or “Channel Parms” (Lightning Control 
Head) menu parameter selects the following conventional channel parameters that can be 
reprogrammed. Press Select switch to select the “Channel Parms” parameter and then 
rotate that switch to display the desired parameter. Then press the Select switch again to 
select it. A single beep sounds when the switch is pressed (if that option is enabled). The 
squelch control parameters are unique to the type of conventional channel selected (analog 
or Project 25).
Note
If “PASSWORD” is briefly displayed when attempting to select a parameter, see 
Section 5.14.2.
Note
If a mixed mode channel is selected, both the Rx Code (analog) and Rx NAC (P25) which 
follow can be programmed. In addition, if the Tx Type is Analog, a Tx Code is 
programmed, and if it is Digital (P25), a Tx NAC is programmed.
RX FREQ - Programs the receive channel frequency. To select the digit to change or 
move the cursor to the right, press the F3 button (Standard Control Head) or right on the 
Navigation Pad (Lightning Control Head). To move the cursor to the left, press the F2 
button (Standard Control Head) or left on the Navigation Pad (Lightning Control Head). 
Then to display the desired digit, rotate the Select switch. The frequency is stored after 
programming the last digit. If an invalid frequency is entered, a beep sounds, 
“INVALID” is briefly displayed, and the frequency editing mode continues to be 
selected.
TX FREQ - Selects the transmit frequency the same the preceding RX FREQ.