E F Johnson Company 2425M80 Benutzerhandbuch

Seite von 207
Draft 02 - Sep 1 2015
7-11
Secure Communication (Encryption)
Key Select - This allows a different key to be selected for the current channel or group 
(Conventional Digital and P25 Trunking channels only). Refer to Section 7.2.4 for 
more information.
OTAR Rekey Request - Sends a message which tells the KMF that the radio is on the 
air and requests rekeying. The following status messages are displayed which indicate 
the progress of this function.
Rekeying - A radio-initiated rekeying session is in process.
No Ack (Standard Control Head)/No Acknowledge (Lightning Control Head) - No 
response was received from the KMF in response to an Identify request before time out 
occurred (approximately 30 seconds).
Ack Recvd (Standard Control Head)/Ack Received (Lightning Control Head) - An 
acknowledgement was received in response to an Identify request.
No Service - A “No Service” reply was received from the KMF. No rekeying will take 
place.
Rekey Fail - Either the rekey command failed or timed out (after approximately 30 
seconds). This message could indicate that the rekey request message was not received 
by the KMF. However, depending on the KMF configuration and channel traffic, it is 
possible that the message was received and a response is still pending.
Rekeyed - The rekey session initiated by the radio was successful.
7.6.4
P25 Trunking Icons
For a Standard Control Head, there are two different P25-data related icons which indicate 
if the radio is on a trunking system. One indicates whether or not you are on a data 
channel, and one indicates whether or not you have successfully data registered (i.e., 
whether or not you were granted an SNDCP data context by the system). The icons appear 
to identical, except for their position on the display.
Under <F3> Button, this icon indicates P25 Data Context Activated – Radio is 
ready for data operations.
Under <F4> Button, this icon indicates Radio is operating on a data channel
There are three different P25-data related icons for the Lightning Control Head which 
indicate if the radio is on a trunking system.  
This icon indicates P25 Data Context Activated - Radio is ready for data 
operations.
This icon indicates Radio is operating on a data channel.
This icon indicates Radio is registered with the Data Registration Server - Radio 
is ready for OTAP operations.