VeriFone RF350 Benutzerhandbuch

Seite von 18
6
 
 Installation
1.
Ensure power to the Ruby is disconnected
2.
Place the unit close to the Ruby.
3.
Uncoil the Multicable and ensure that it does not kink or is 
not placed under heavy equipment.
4.
Mount the unit on a custom stand, if applicable.
5.
Insert the RS232 cable connector from the Ruby into the 
Multicable jack labeled PORT 1.
6.
Apply power to the Ruby.
Equipment Power Up
The Verifone VeriPASS Terminal is powered from the Ruby 
Terminal through a serial cable. This feature eliminates the need for 
an optional power supply. 
Note:
The VeriPASS Terminal may be powered by an 
optional external power supply (VeriFone P/N: 
04250-05).
Use the following procedures to power up the VeriFone Indoor 
VeriPASS Terminal unit using the optional power supply:
PO
R
T
 1
Multicable
Ruby
Ferrite Bead
VeriFone
Indoor 
VeriPASS
Terminal
Serial Cable
P/N: 13836-01 
Co
m
 P
o
rt
*
* Consult VASC Service Manual to 
  determine the correct com port for
  your application.