Ethernet
Connection with
External Power
Brick
The cable required junction box that provides a standard RJ-45 LAN socket and a 
DC jack. However, since most hosts do not support peer-to-peer LAN connection 
to a PIN pad, an additional RJ-45 socket is provided on the junction box to allow a 
direct connection between V
x
810 and the host.
Figure 1
6
Ethernet Connection with External Power Brick
Power Supply
Not all V
x
810 configurations and device contexts require the use of a power 
supply – VeriFone ships power supplies with the V
x
810 as required.
If you have changed the context in which the V
x
810 is used or have questions 
about which power supply should be used, contact your VeriFone representative.
Before connecting a power supply, disconnect the power pack cord from the 
power outlet.
Connect and route all cables between the V
x
810, ECR, and PC before plugging 
the power pack cord into a wall outlet or surge protector.
When the V
x
810 has power and an application is loaded, the application starts 
after the initial VeriFone copyright screen and displays a unique copyright screen. 
If no application is loaded, 
DOWNLOAD NEEDED
 appears on the display after the 
initial VeriFone copyright screen.
CAUTION
Using an incorrectly rated power supply can damage the unit or cause it not to 
work properly. Use only a power pack with VPN CPS11212-3A-(R) (see 
Specifications
 for detailed power supply specifications).
WARNING
Do not plug the power pack into an outdoor outlet or operate the V
x
810 outdoors. 
Also, disconnecting power during a transaction can cause transaction data files 
not yet stored in memory to be lost.
NOTE
To protect against possible damage caused by lightning strikes and electrical 
surges, VeriFone recommends installing a power surge protector.