Troubleshooting 
Use the following guidelines if the system does not respond 
correctly when the sensor final testing is conducted. 
• 
Check programming and re-program sensor into panel if 
necessary. 
• 
Move the sensor to another location and test for correct 
response. 
• 
Check the mounting height and angle are according to 
“Mounting” section. 
To Relocate a Sensor 
1.  Test the sensor a few inches from the original position. 
2.  Increase the distance from the original position and 
retest until an acceptable location is found. 
3.  Mount the sensor in the new location. 
4.  If no location is acceptable, test the sensor as described 
below: 
• 
Test a known good sensor at the same location. 
• 
If the system does not respond, avoid mounting a sensor 
at that location. 
• 
If the replacement sensor functions, return the problem 
sensor for repair or replacement. 
Specifications  
60-807-95R 
RF Frequency 
319.5 MHz 
Compatibility 
Interlogix 319.5 MHz control panels/receivers 
Battery Type 
Two AA Alkaline Batteries 
Typical Battery Life 
2 – 4 years at 68° F (20° C) 
Operating 
Temperature Range 
32° to 110°F (0° to 43°C) Non-pet 
applications 
60° to 110°F (16° to 43°C) Pet applications 
Supervisory Interval 
64 Minutes 
Relative Humidity 
0 – 90% non-condensing 
Storage Temperature 
Range 
-30 to 140°F (-34 to 60°C) 
Weight 
0.3 lbs (0.136 kg) 
Dimensions 
(L x W x H) 
2.875 x 2.375 x 1.875 in. 
(7.303 x 6.033 x 4.763 cm)  
 
60-807-01-95R 
RF Frequency 
319.5 MHz 
Compatibility 
Interlogix 319.5 MHz control panels/receivers 
Battery Type 
One AA Lithium Battery 
Interlogix part #60-619 
Typical Battery Life 
4 – 6 years at 68° F (20° C) 
Operating 
Temperature Range 
32 to 120°F (0 to 49°C) Non-pet applications 
60 to 120°F (16 to 49°C) Pet applications 
Supervisory Interval 
64 Minutes 
Relative Humidity 
0 – 90% non-condensing 
Storage Temperature 
Range 
-30 to 140°F (-34 to 60°C) 
Weight 
0.3 lbs (0.136 kg) 
Dimensions 
(L x W x H) 
2.875 x 2.375 x 1.875 in. 
(7.303 x 6.033 x 4.763 cm)  
60-807-02-95R 
RF Frequency 
319.5 MHz 
Compatibility 
Interlogix 319.5 MHz control panels/receivers 
Battery Type 
Two 1.5V AA Lithium Iron Disulfide Batteries 
(Interlogix part # 60-931, six pack of 
batteries).  
Note: Use only AA 1.5 Volt Lithium Iron 
Disulfide batteries (part # 60-931) with this 
product. Do not substitute any other 
brand/type of batteries. 
Typical Battery Life 
2-5 years at 68° F (20° C) 
Operating 
Temperature Range 
32 to 120°F (0 to 49°C) Non-pet applications 
60 to 120°F (16 to 49°C) Pet applications 
Supervisory Interval 
64 Minutes 
Relative Humidity 
0 – 90% non-condensing 
Storage Temperature 
Range 
-30 to 140°F (-34 to 60°C) 
Weight 
0.3 lbs (0.136 kg) 
Dimensions 
(L x W x H) 
2.875 x 2.375 x 1.875 in. 
(7.303 x 6.033 x 4.763 cm)