UTC Fire & Security Americas Corporation Inc 680F-PIR Benutzerhandbuch
PET Immune SAW PIR Motion Sensors Installation Sheet
5 / 6
Troubleshooting
Use the following guidelines if the system does not respond
correctly when the sensor final testing is conducted.
correctly when the sensor final testing is conducted.
•
Check programming and re-program sensor into panel if
necessary.
necessary.
•
Move the sensor to another location and test for correct
response.
response.
•
Check the mounting height and angle are according to
“Mounting” section.
“Mounting” section.
To Relocate a Sensor
1. Test the sensor a few inches from the original position.
2. Increase the distance from the original position and
retest until an acceptable location is found.
3. Mount the sensor in the new location.
4. If no location is acceptable, test the sensor as described
below:
•
Test a known good sensor at the same location.
•
If the system does not respond, avoid mounting a sensor
at that location.
at that location.
•
If the replacement sensor functions, return the problem
sensor for repair or replacement.
sensor for repair or replacement.
Specifications
60-807-95R
RF Frequency
319.5 MHz
Compatibility
Interlogix 319.5 MHz control panels/receivers
Battery Type
Two AA Alkaline Batteries
Typical Battery Life
2 – 4 years at 68° F (20° C)
Operating
Temperature Range
Temperature Range
32° to 110°F (0° to 43°C) Non-pet
applications
60° to 110°F (16° to 43°C) Pet applications
applications
60° to 110°F (16° to 43°C) Pet applications
Supervisory Interval
64 Minutes
Relative Humidity
0 – 90% non-condensing
Storage Temperature
Range
Range
-30 to 140°F (-34 to 60°C)
Weight
0.3 lbs (0.136 kg)
Dimensions
(L x W x H)
(L x W x H)
2.875 x 2.375 x 1.875 in.
(7.303 x 6.033 x 4.763 cm)
(7.303 x 6.033 x 4.763 cm)
60-807-01-95R
RF Frequency
319.5 MHz
Compatibility
Interlogix 319.5 MHz control panels/receivers
Battery Type
One AA Lithium Battery
Interlogix part #60-619
Interlogix part #60-619
Typical Battery Life
4 – 6 years at 68° F (20° C)
Operating
Temperature Range
Temperature Range
32 to 120°F (0 to 49°C) Non-pet applications
60 to 120°F (16 to 49°C) Pet applications
60 to 120°F (16 to 49°C) Pet applications
Supervisory Interval
64 Minutes
Relative Humidity
0 – 90% non-condensing
Storage Temperature
Range
Range
-30 to 140°F (-34 to 60°C)
Weight
0.3 lbs (0.136 kg)
Dimensions
(L x W x H)
(L x W x H)
2.875 x 2.375 x 1.875 in.
(7.303 x 6.033 x 4.763 cm)
(7.303 x 6.033 x 4.763 cm)
60-807-02-95R
RF Frequency
319.5 MHz
Compatibility
Interlogix 319.5 MHz control panels/receivers
Battery Type
Two 1.5V AA Lithium Iron Disulfide Batteries
(Interlogix part # 60-931, six pack of
batteries).
(Interlogix part # 60-931, six pack of
batteries).
Note: Use only AA 1.5 Volt Lithium Iron
Disulfide batteries (part # 60-931) with this
product. Do not substitute any other
brand/type of batteries.
Disulfide batteries (part # 60-931) with this
product. Do not substitute any other
brand/type of batteries.
Typical Battery Life
2-5 years at 68° F (20° C)
Operating
Temperature Range
Temperature Range
32 to 120°F (0 to 49°C) Non-pet applications
60 to 120°F (16 to 49°C) Pet applications
60 to 120°F (16 to 49°C) Pet applications
Supervisory Interval
64 Minutes
Relative Humidity
0 – 90% non-condensing
Storage Temperature
Range
Range
-30 to 140°F (-34 to 60°C)
Weight
0.3 lbs (0.136 kg)
Dimensions
(L x W x H)
(L x W x H)
2.875 x 2.375 x 1.875 in.
(7.303 x 6.033 x 4.763 cm)
(7.303 x 6.033 x 4.763 cm)