UTC Fire & Security Americas Corporation Inc 785B-ALGRO Benutzerhandbuch

Seite von 31
25
Allegro
Preliminary 2/5/02
DL Code (12345)
5 digit code, 0-9
Install Code, 4321 
4 digit code, 0-9
Dealer Code, none 
4 digit code, 0-9
Duress Code, none 
4 digit code, 0-9
Apartment Manager Code, none 
4 digit code, 0-9
Entry DLY, 30 
30-240 
Exit DLY, 60 (60 for UL1023)
45-254
PH TST Freq, 7 
1-255
NXT PH Test, 7 
1-255
Sleepy Time, on (off for UL installations)
off, on
Sleep Hour, 22 
0-23
KTP Arm, off 
off (ratchet arm), on (all on), No Delay
Police Panic, on 
off, on
Emergency Panic, off 
off, on
Fire Panic, on 
off, on
Rcvr Trouble, off (on for UL installations)
off, on
Panel Tamper, on 
off, on
Exit EXT, on (off for UL installations)
off, on
Swinger Shutdown, 1 
1-2 
Quick Arm, off 
off, on
Quick Exit, on (off for UL installations)
off, on
Auto Stay Arm, on 
off, on
Supv Time, random 
1 am - 5 am
Alarm Verify, off (off for UL installations)
off, on
Demo Kit, off 
off, on
AC Fail, off (on for UL 1635)
off, on
Low CPU Battery, on (on for UL 1635)
off, on
Phone Test, on 
off, on
Auto Phone Test, off (on for UL 1635)
off, on
Siren Time Out, 4 (min for UL installations) 1-30
Trouble Beeps, on (on for UL installations)
off, on
Alarm Volume, 6 (min for UL installations)
0-6
Table B2: System Settings (Continued)
Menu Name & Default
Parameters
Settings