Volansys Technologies pvt ltd GW6UL01M2M4 Benutzerhandbuch
Modular IoT Gateway User Manual
Rev0.4
Confidential
Copyright © 2016 Volansys
August 17, 2017
Volansys Technologies
Page |
15
When using serial download option for Boot, USB-2(J17) will be used in Device mode. It is required to
change Jumper setting to enable device mode.
change Jumper setting to enable device mode.
4.4 USB Debug Port
The Modular IoT Gateway comes with one microUSB debug port support to simplify debugging
mechanism. A CP2102, USB to serial UART IC is used to convert the UART signals to USB. A micro-B to
standard A USB cable can be used. UART1 port is used as the debug port.
The required terminal settings are shown in the following table:
mechanism. A CP2102, USB to serial UART IC is used to convert the UART signals to USB. A micro-B to
standard A USB cable can be used. UART1 port is used as the debug port.
The required terminal settings are shown in the following table:
Baud Rate
115200
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
None
Table 5 - Terminal Settings
4.5 Wi-Fi and Bluetooth
Modular IoT Gateway provides support of Single Band (2.4GHz) Wi-Fi and Bluetooth using Murata’s
LBEE5KLDX RF module on Gateway.
LBEE5KLDX RF module on Gateway.
The Modular IoT Gateway supports following features:
Support of single band IEEE 802.11b/g/n Wi-Fi
Bluetooth ver. 4.1 BLE
Bluetooth ver. 4.1 BLE
Provides SDIO interface for Wi-Fi and UART interface for Bluetooth operation
External u.fl connectors is connected with antenna line of module to provide external Whip
External u.fl connectors is connected with antenna line of module to provide external Whip
antenna support
4.6 User Interface Switch
4.6.1 Commissioning Switch (SW1)
SW1 is used to start/stop NFC commissioning mode. It is also used to power off the gateway board by
long pressing it for more than 15 sec.
long pressing it for more than 15 sec.