ELECTRONICIGNITIONSYSTEMS 
Please DO take following tests and make sure all functions are working fine: 
1.  Slide the slide switch button on the receiver to the ON (Fig. 16). The spark igniting electrode should begin 
sparking to ignite the pilot. Once the pilot flame is lit, the main gas valve should open and the main gas fire flame should 
be ON. 
2.  Slide the button to OFF. The main gas fire flame and pilot fire flame should extinguish together. 
3.  Slide the button to REMOTE, and then press the MODE button on the transmitter to change the system to ON. 
The spark igniting electrode should begin sparking to ignite the pilot. Once the pilot flame is lit, the main gas valve should 
open and the main gas fire flame should be ON. 
4.  Press the MODE button to OFF. The main gas fire flame and pilot fire flame should extinguish together. 
5.  Press the MODE button on the transmitter to change the system to THERMO
*2
. Make the SET temperature on 
the transmitter to a temperature of a least 2°F (1°C) above the ROOM temperature displayed on the LCD screen, the 
system flame and main gas fire flame will be ON. Then make the SET temperature to at least 2°F (1°C) below the 
ROOM temperature, the system flame and main gas fire flame will extinguish in seconds. It should continue to cycle ON 
and OFF thermostatically. The temperature differential between ROOM and SET temperatures differ at least 2°F (1°C) 
to start the THERMO
*2
 cycling. (The 2°F differential is the factory setting, can NOT be changed.) 
 
 
ADDITIONALINFORMATION 
 
THERMOSAFETYPROTECTION FORRECEIVER 
 
In order to protect the receiver box, batteries, and receiver’s microprocessors, the Durablow remote control system 
equips a THERMISTOR, a safety feature in receiver box. 
The THERMISTOR will automatically shut the system and appliance down,& begin makingBEEP X 3 (♫, ♫, ♫), every 4 
seconds, when the temperature inside the receiver boxis higher than 130°F (54°C). User can re-activate the system by 
pressing the MODE button on the transmitter when  the  receiver temperature drops between 120°F (48°C) and 130°F 
(54°C). 
However, the BEEPING will NOT stop if the temperature remains between 120°F and 130°F until the temperature drops 
below 120°F. The beeping is to alert user that the receiver should be re-located at a cooler position. 
To completely reset the beeping and 
THERMISTOR,  please press the MODE button to make a mode cycle (OFF-ON-
OFF). Please make sure & allow some time for the receiver box to cool down below 120°F .  
 
 
TRANSMITTER
 
 
1. 
TRANSMITTEROPERATINGDISTANCE
 
 
Thetransmitter uses RF radio frequency to send signal to receiver. Itis strongly recommendedtouse thetransmitter 
within20-foot distance from receiver box in the same room / space (no wall partition).
 
 
2. THERMO
*2
DETECTING INTERVAL IN TRANSMITTER 
The transmitter normally detects the ROOMtemperature every 2 minutes against theSETtemperature by sending a signal 
tothe receiver.
 
 
3.  OUT-OF-RANGE SAFETY ALERT IN TRANSMITTER 
 
 
 