Polysense Technologies Co. Ltd. WXS8000 Benutzerhandbuch

Seite von 36
 
 
User Guide 
Revision 0.1 
 
 
XXX-XXXX 
Polysense WxS8000 User Guide 
Rev 2.3, Mar 26, 2018 
 
Polysense, Inc. Confidential 
Page 8 
 
 
3.  Quick Start 
By default, WxS8000 works in OTA (Over The Air) activation mode, below table shows WxS8000 
default settings, which are saved in WxS8000 local FLASH and called as PPB (Polysense Personality 
Base). For individual WxS8000 specific settings, including MoteEUI, sensor specific configurations, 
please refer to Polysense WxS8000 Factory Settings document. 
User can follow below procedure to connect WxS8000 to LoRa network: 
1.  Configure the LoRa server to add the new end-device (or mote) according to WxS8000 default 
settings 
2.  If US902 or CN470 region is being used, then it is necessary to follow below settings to 
configure the LoRa gateway upstream channel plan (in order to align with WxS8000 factory 
settings): 
 
US902: 902.3, 902.5, 902.7, 902.9, 903.1, 903.3, 903.5, 903.7 
 
CN470: 470.3, 470.5, 470.7, 470.9, 471.1, 471.3, 471.5, 471.7 
3.  Install the external antenna (screw the external antenna on the SMA connector on enclosure) if 
the WxS8000 doesn’t have internal coil antenna installed 
4.  Power on WxS8000 either via connecting the DC power supply or plugging the 3.6V LI/SOCl2 AA 
battery into the battery holder (if the AA battery is used as power source, PLEASE ensure the 
AA battery polarities are consistent with the silk-screen on PCB)  
 
NOTE: There is NO AA battery inside WxS8000 box initially 
5.  WxS8000 starts the OTA join procedure and try to register to the nearby LoRa gateway/server 
 
Item 
Value 
Region 
1 (CN) 
Scheduling granularity 
30 seconds 
LoRa class 
0 (Class A) 
Join type 
0 (OTA - Over The Air) 
Disable PRB (Polysense 
Runtime Base) 
0 (disabled, so that WxS8000 will always initiate OTA procedure every 
time after reboot) 
Enable ADR 
1 (enabled) 
Use fixed device nonce 
0 (WxS8000 will use the device nonce generated randomly when 
joining the server in OTA mode) 
Device EUI 
(Refer to the label on WxS8000 enclosure) 
Application EUI 
Application key 
11-22-33-44-55-66-77-88-99-00-AA-BB-CC-DD-EE-FF