Wellmike Technology Co. Ltd WM-E104 Benutzerhandbuch

Seite von 19
 
                                                                                                                       
2.0 Connecting System:      
 
As shown in Fig. 3, 4:   
    2.1). Connect the LPG regulator hose/NG hose to the brass connector in the valve box. (Fig.3, 4) 
  2.2). 
Connect the “Out” connector in valve box to burner assembly with black flex hose. (fig.xx)   
  2.3). Connect Pilot Light output connector in valve box to Pilot Light fixture in the burner via the copper pipe.   
  2.4). Attach the wire with red mark to the ignition, the one with black mark to the thermocouple sensor 
respectively.   
    2.5). Connect the controller with valve box with the 8-pin data transferring cable. Screw back the Aerial protective 
head.   
2.6). Plug in the LED strip to the LED slot in the back of controller by following polarity arrows.     
  2.7). Connect the Speaker to the Line-out Slot in the back of Controller by following correct polarities(Fig. 2, 4).   
    2.8). Plug in the AC/DC adapter(19V/4.74A) to the back power socket of controller 
                2. 9). 
When the connection is completed, check joints to make sure they’re properly installed, especially for the   
gas pipes & joints to avoid risk of gas leakage. (Suggest using soap liquid to check pipes & connection)   
 
 
                                                                 
  Fig 3-4