Avanti Hearth Products LLC Z60 Benutzerhandbuch

Seite von 15
②  Thermostat Indicator – Thermo Off appears when it’s manually on; Thermo On appears 
when thermostat is activated. 
③  Manual On/ Temp Set – ON shows when it’s manually turned on; set temperature shows 
when thermostat is in operation 
④  Clock – Indicates the current time in AM/PM 
⑤  Room – Indicates current room temperature 
⑥  Flame – Indicates burner/ valve in operation 
⑦  Battery – Battery power is low. Replace batteries within 2 weeks 
⑧  Timer  –  Indicates time remaining before system shuts off when timer-programmed; 9-hour 
maximum setting 
⑨  Lock – Childproof lock-out 
 
       
3. 
Control Buttons 
ON/OFF
UP
TIMER/
CLOCK
THERMOSTAT
DOWN
SET
 
 
       
3. 
Setting the Clock 
      (1) Press and hold the “Timer/Clock” button for more than five seconds, the 
hour digit(s) will begin flashing.   
(2) Press the  ▲  (UP) or  ▼  (DOWN) button until the desired hour is         
displayed in AM or PM.   
(3) After setting the desired hour, push the “Timer/Clock” button again to set 
the minutes. The minute digits will begin flashing. 
(4) Press the  ▲  (UP) or  ▼  (DOWN) button until the desired minute is displayed.   
(5) Press the SET button, the minute digits will stop flashing, indicating the clock has been 
successfully set. 
Note: Flashing digits on LCD indicate the system is awaiting user’s input as mentioned above. 
The digits will stop flashing if no input is made within 10 seconds and the setting is 
automatically completed.   
   
       
4. 
Setting ℉
 / 
 Scale 
The factory setting for temperature is ℉(Fahrenheit).  
To change this setting to ℃(Celsius): 
(1)  Remove the battery cover on the back of the transmitter. 
F
AM
ROOM
o
F
o
C
+
_ AAA
+
_
AAA
o
F/
o
C Switch