inside mounting plate and replace rear cover.  If using external 
contacts, skip to Step 7. 
6.   Install mounting plates.  Use #6 flat-head screws to secure, 
observing reed switch alignment mark.  Mount magnet housing 
within 5/8" of the transmitter cover.  For internal contacts, skip to 
Step 9. 
7.   (For external contacts only).  Install contact or sensor and 
transmitter mounting plate.  Mount the contact or sensor as 
described in its instructions.  For recessed wiring, carefully drill 
an access hole for the wires. 
8.   (For external contacts only).  Insert wire plug into receptacle 
on PC board (curl wires inside case to avoid pinching wires); 
connect two wires to an external sensor having normally-closed 
contacts (or a normally-closed loop).  Set Jumper J1 to "LOOP".  
9.   Complete transmitter setup.  If internal reed switch is used, 
set Jumper J1 to "MAG".  If both internal reed switch and exter-
nal contacts are used, remove Jumper J1 (see table below).   
10. Close the transmitter case.  Close the case by engaging the 
retaining tabs at either end, then snapping the front cover to the 
mounting plate.  Be careful not to pinch wire harness (if used). 
11. Program the panel.  Each transmitter has a unique factory-
programmed ID code that distinguishes itself to the receiver.  
Enter (a) the zone number to which the transmitter will be 
mapped; (b) the 6-digit ID code with checksum digit; and (c) the 
wireless point number.  See control-panel instructions for 
entering this ID code and checksum digit into the panel; be sure 
to enter all numbers and/or letters, including leading zeros, if 
any.  Note:  Program for "point 1" for all wiring options.  Note: In 
UL burglary installations, program the burglary alarm output for 
all protective devices. 
 
WIRING OPTIONS 
     The GEM-TRANSLP may be wired in any of the following 
configurations.  Refer to the following table: 
GENERAL DESCRIPTION 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
     The GEM-TRANSLP is a low profile window/door transmitter 
designed for use in Napco GEM-series wireless systems.  When 
used with the supplied magnet, the transmitter functions as a 
window/door sensor.  However, plug-in wires are provided for nor-
mally-closed external contacts so that one or two additional devices 
may be used in conjunction with (or instead of) the internal reed 
switch.  A jumper is provided allowing optional use of normally-
closed external contact
 
(s) and/or internal reed switch.   
 
    The GEM-TRANSLP is powered by a 3-volt lithium battery 
(Energizer CR2032 or Duracell DL2032), that powers the 
transmitter for up to 5 years.  When battery voltage drops below 
normal, a low-battery report will be sent to the receiver. 
 
INSTALLATION 
      Notes:    The transmitter and magnet may be mounted in any 
position with no degradation in performance.  Thus, if a left-handed 
reed switch is required, the unit may be mounted upside down.  
However, for reference purposes in this text, the transmitter will be 
considered oriented with the reed switch at the top, as shown in 
Fig. 1.  The PC board snaps into the transmitter front cover in only 
one direction; a raised alignment mark on the transmitter front cover 
indicates the location of the reed switch on the PC board.  There is 
also an alignment mark on the magnet mounting plate. 
 
1.     Open the case.  Remove the GEM-TRANSLP transmitter cover 
from its mounting plate by inserting a small screwdriver into ei-
ther slot; twist while applying upward pressure.  See Fig. 2. 
2.     Insert the battery.  Observe battery polarity.  Insert battery un-
der the two gold contacts with the positive (+) terminal towards 
you (facing up).  See Fig. 3.  Do not insert backwards. 
3.     Identify PC Board parts.  Note location of reed switch in Fig. 1. 
4.     Select transmitter location.  Avoid mounting the transmitter 
near the floor.  Low level mounting can reduce transmission 
range and may subject the transmitter to damage. 
5.     Install magnet.  Insert a small screwdriver into either retaining 
tab in rear cover; push in and twist to separate.  Insert magnet 
R
333 Bayview Avenue 
Amityville, New York 11701 
For Sales and Repairs, (800) 645-9445 
For Technical Service, (800) 645-9440 
 
Publicly traded on NASDAQ    Symbol: NSSC
 
© NAPCO 2008 
GEM-TRANSLP  
Low Profile Window / Door Transmitter 
INSTALLATION INSTRUCTIONS 
Fig. 2.  Opening the case 
Fig. 3.  Install battery under gold contacts 
1.  Push up 
2.  Twist 
 
GOLD CONTACTS 
Fig. 1.  GEM-TRANSLP Component Parts 
MAGNET 
TRANSMITTER 
MOUNTING PLATE 
PC BOARD 
FRONT COVER 
MOUNTING PLATE 
REAR COVER 
R
EE
D
 S
W
IT
CH 
WIRING OPTIONS 
OPTION JP1 
SETTING 
FUNCTION 
DIAGRAM 
1. 
 
"LOOP":   
External contact  
enabled for point 1; 
magnetic internal 
contact (reed switch) 
disabled.  
 
2. 
 
JUMPER REMOVED: 
External contact  
enabled for point 1 
and magnetic internal 
contact (reed switch) 
enabled for point 1. 
 
3. 
 
"MAG": 
Magnetic internal 
contact enabled for 
point 1; external con-
tact disabled. 
 
 
Notes:   
1. Caution:  Changes or Modifications not approved by NAPCO may void 
the user's authority to operate the equipment. 
2. This device may not cause interference. 
3. This device must accept any interference, including interference that 
may cause undesired operation of the device. 
N.C. EXTERNAL  CONTACT ON 
POINT 1 ("LOOP") 
 
 
JUMPER REMOVED TO ENABLE 
BOTH N.C. EXTERNAL AND N.C. 
INTERNAL CONTACTS ON POINT 1  
 
 
(REED SWITCH) 
N.C. INTERNAL CONTACT ON 
POINT 1 ("MAG") 
WI1667A.02  4/08 
DL2032 or 
CR2032 
DL2032 or 
CR2032 
Note:  For a replacement wire harness, order part # W978. 
JP1 
MAG 
LOOP 
JP1 
MAG 
LOOP 
JP
MAG 
LOOP 
MAGNETIC REED SWITCH ONLY