ICOM 325300 Benutzerhandbuch

Seite von 96
28
5
REPEATER AND DUPLEX OPERATIONS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
N 1750 Hz tone
To access some European repeaters, the transceiver must 
transmit a 1750 Hz tone burst. For such European repeaters, 
perform the following.
• This tone can be use as a ‘Call signal’ in countries out of Europe.
q  Push [SET] to enter the Set mode.
w  Rotate [DIAL] to select the DTMF key item, then rotate 
[VOL] to set to “t-CALL.”
[VOL]
[DIAL]
Tone call setting
DTMF key setting
ePush [V/M/C] to return to the frequency display.
r  Set the receive frequency 
(repeater output frequency)
.
t  Set the shift direction of the transmit frequency. 
(–DUP or 
+DUP; see p. 26 for details.)
y  While continuing to push [PTT], push [MONI](BAND) to 
transmit a 1750 Hz tone burst signal.
• If “OFF” appears, check the frequency offset or shift direction. 
(p. 26)
• The displayed frequency automatically changes to the transmit 
frequency (repeater input frequency).
uPush and hold [PTT] to transmit.
iRelease [PTT] to receive.
o  Push and hold [MONI](BAND) to check whether the other 
station’s transmit signal can be received directly or not, by 
listening on the repeater input frequency.
 CONVENIENT! (For the IC-T70E only)
q  Set the receive frequency 
(repeater output frequency)
.
w  Set the shift direction of the transmit frequency. 
(–DUP or 
+DUP; see p. 26 for details.)
e  Push [PTT] briefly, then push and hold [PTT] again for 1 to 
2 sec. to transmit a 1750 Hz tone burst signal.
• If “OFF” appears, check the frequency offset or shift direction. 
(p. 26)
• The displayed frequency automatically changes to the transmit 
frequency (repeater input frequency).
rPush and hold [PTT] to transmit; release to receive.