Smartrise Engineering Inc RFI1 Benutzerhandbuch

Seite von 6
PROGRAMMING THE READER 
(REQUIRES ACCESS TO COP BOARD) 
 
 
 
1
.   Plug the reader into the COP Drive port using a standard CAT5 cable. 
2.   Turn on Dip Switch #2. [This will be left on when programming or using the RFID-1 reader]
3.   Turn on Dip Switch #3 (#2 & #3 are now on) and swipe  a tag across the reader. This will program 
that tag as the Manager Tag which will be needed to program the User Tags. 
4.    Turn on Dip Switch #4 (#2, #3 & #4 are now on) and swipe the Manager Tag (programmed in step 
#3).  This  will  delete all  tags  that  may  be  programmed in  system, including  the  new Manager Tag 
programmed in Step #3. 
5.   Turn  off  Dip  Switch  #4  and  swipe  a  tag  across  the  reader  reprogramming it  as  the  new 
Manager Tag. 
6.   Turn  off Dip  Switch  #3 (#2 is  the only switch that will stay on). Now you’re ready to program the 
User tags. 
 
LED Patterns – Programming the Reader 
 
Red / Green Blinking w/short 
pause between blinking 
Manager Tag programmed successfully 
Red / Green Blinking w/long 
pause between blinking 
Delete all tags successful 
 
 
PROGRAMMING THE USER TAGS 
 
 
1.   
With  the  solid  red  light  on,  swipe  the  Manager  Tag  across  the  face.  You  should  have  a solid 
green light with a brief red flash showing the reader is in programming mode. 
2.    Swipe  the  un-programmed  tag  across the  reader. The  LED  should  be  solid  red  with  a  brief green 
flash showing that the new tag is recognized.   The Car Call Lamps (CCL) will display the tag ID (001 
for 1
st
 tag, 002 for second tag, etc.) in Binary. The following table shows an example of a 4-stop car 
and the Car Call Lamps that correspond with the tag ID. 
 
Tag Description 
ID# 
Floor 1 CCL 
Floor 2 CCL 
Floor 3 CCL 
Floor 4 CCL 
Master Tag 
0000   
 
 
 
User  Tags 
0001 
 
 
 
0002   
 
 
0003 
 
 
0004   
 
 
0005 
 
 
0006   
 
0007 
 
0008