CBF Networks Inc. dba Fastback Networks LIB-V1000E2 Benutzerhandbuch
Liberator-V1000 User Manual
Rev 04v05
Page
74
of
85
FBN Doc #: FBN-0125_04v05
Configuration Item
Web Page
MIB Object
Use DHCP
Administration / Management / IP
sub10UnitMgmtIpDHCP
IP Address
Administration / Management / IP
sub10UnitMgmtIpAddress
Subnet Mask
Administration / Management / IP
sub10UnitMgmtIpSubnetMask
Default Gateway
Administration / Management / IP
sub10UnitMgmtIpDefGateway
Enable VLAN Management
Administration / Management / IP
sub10UnitMgmtVlanState
Management VLAN Id
Administration / Management / IP
sub10UnitMgmtVlanId
Management VLAN Priority Administration / Management / IP
sub10UnitMgmtVlanPriority
Management VLAN DEI
Administration / Management / IP
sub10UnitMgmtVlanDEI
SNMP
Administration / Unit
sub10UnitMgmtServiceSnmp
Read Community
Administration / Management / SNMP
sub10UnitMgmtSnmpReadCommunity
Write Community
Administration / Management / SNMP
sub10UnitMgmtSnmpWriteCommunity
Synchronous Ethernet
Administration / SyncE
sub10UnitMgmtSyncEMode
Encryption
Administration / Security / Encryption sub10UnitMgmtEncryptMode
Enable VLAN Filtering
Administration / VLAN
sub10EthMgmtVlanFiltering
Allowed VLAN
Administration / VLAN
sub10EthMgmtVlanAllowedId
Enable Default VLAN
Administration / VLAN
sub10EthMgmtVlanDefaultEnabled
Default VLAN Id
Administration / VLAN
sub10EthMgmtVlanDefaultId
Default VLAN Priority
Administration / VLAN
sub10EthMgmtVlanDefaultPriority
Default VLAN DEI
Administration / VLAN
sub10EthMgmtVlanDefaultDEI
Enable ATPC
Administration / Radio
sub10RadioMgmtAPCMode
Transmit Power level
Administration / Radio
sub10RadioMgmtTxPowerLimit
Maximum Modulation Mode Administration / Radio
sub10RadioMgmtModulationMode
Tx/Rx Frequencies
Administration / Radio
sub10RadioMgmtTxRxFreq
Switch Bank & Reboot
1
Maintenance / Firmware
sub10UnitMgmtFirmwareSelectBank /
sub10UnitMgmtFirmwareAction=fmw
Reboot(2)
sub10UnitMgmtFirmwareAction=fmw
Reboot(2)
Table 3 - Configuration Confirmation / Rollback Table
1
The configuration rollback option is required after a bank change and reboot. Upon the next restart login to the unit’s web GUI to view
the confirm / rollback option. IMPORTANT NOTE: A rollback (manually or automatic after timeout) after a firmware bank change and
reboot will cause the unit to switch back to the original bank and reboot the unit again.
reboot will cause the unit to switch back to the original bank and reboot the unit again.