REMARQUE:  La  date  de  remplacement  fi gurant  sur  l’appareil  est  la  date 
à  partir  de  laquelle  l’appareil  risque  de  ne  plus  détecter  correctement  le 
monoxyde de carbone et à laquelle il doit donc être changé.
ATTENTION
SPECIFICATIONS 
•  Source d’alimentation: Un 3 volts CR123A Panasonic Batterie au lithium 
(inclus) 
•  Signal sonore (temp 4 de ton): 85 dBA min. en alarme (à 10 pieds (3 m)) 
•  Courant de fonctionnement: 10 µ A 
•  Température: 40 ° F (4,4   ° C) à 100 ° F (37,8 ° C) 
•  Humidité  en  fonctionnement:  15%  à  95%  d’humidité  relative,  sans 
condensation 
•  Attente Listes Agence: la norme UL 2075, UL 2034 et CSA 6.19-01
Qolsys
2011 Stevens Creek Blvd.
Cupertino, CA 95014
www.qolsys.com
3
APD0597 A140618 Qolsys IQCO (QS-5210-PO1) Wireless CO Install Guide
Detector  Trouble:  When  the  sensor  supervision  is  in  trouble  condition, 
the yellow LED blinks once every six seconds and there is a chirp every 45 
seconds. After 12 hours the panel will display a loss of supervision message.
Detector end of life feature: When the detector has reached the end of its life, 
the yellow LED blinks once every 23 seconds and there is a chirp every 45 
seconds. After 12 hours the panel will display a loss of supervision message. 
This indicates that the CO sensor inside the detector has passed the end of 
its life and the detector must be replaced. The detector lifespan is fi ve years 
from the date of manufacture. Refer to DETECTOR REPLACEMENT section.
Low Battery Detection: The Wireless Carbon Monoxide Alarm is powered 
by  a  single  3-volt  CR123A  Panasonic  Lithium  battery  (included).  The 
detector  regularly  checks  for  a  low  battery.  If  a  low  battery  is  detected, 
the  transmitter  sends  a  low  battery  message  to  the  control  panel,  which 
displays the detector’s ID at low battery. In addition, the yellow LED of the 
detector will blink every 12 seconds. The detector’s sounder will chirp every 
45  seconds  (yellow  LED  continues  to  blink)  until  the  battery  is  replaced. 
Pressing the hush button will silence the chirps for 12 hours, if no other 
trouble conditions exist. The battery should be replaced WHEN the chirps 
begin. Be sure to replace the battery with a fresh one. 
Unauthorized changes or modifi cations could void the user’s authority to 
operate the equipment.
BATTERY INSTALLATION AND REPLACEMENT
To replace the battery:
1.  Remove the detector from its mounting base by twisting the detector 
counterclockwise.  Remove  and  dispose  of  the  battery  according  to 
your local regulations.
2.  2.  To  ensure  proper  power-down  sequence,  wait  a  minimum  of  20 
seconds before installing new battery.
3.  Install a new 3-volt CR123A Panasonic Lithium battery (available from 
your Panasonic dealer) in the battery compartment. Follow the polarity 
diagram inside the compartment. If the battery is incorrectly inserted 
please remove gently with a non-conductive tool and correctly reinsert.
4.  Reinstall the detector onto the mounting base by turning the detector 
clockwise.
5.  After the power-up sequence the green LED should blink about once 
every  12  seconds  to  indicate  normal  operation.  If  the  battery  is  not 
Veuillez noter que l’installation, le fonctionnement, le test et l’entretien de 
cette alarme sans fi l de détection du monoxyde de carbone, différent de 
ceux des detecteurs de fumée. Selon la section 5.3.7.2 de la norme NFPA 
720    le  détecteur  ne  doit  pas  être  connecté  à  une  zone  pouvant  émettre 
des signaux concernant un incendie (ex. des zones équipées de détecteurs 
de  fumée).  Cette  alarme  sans  fi l  de  détection  du  monoxyde  de  carbone 
doit donc être programmée en tant que zone sans détection d’incendie. Se 
reporter aux instructions d’installation du contrôle pour obtenir le type de 
zone concernant le monoxyde de carbone devant être programmé.
This  device  complies  with  Part  15  of  the  FCC  Rules  and  with  Industry 
Canada  license-exempt  RSS  standard(s).   Operation  is  subject  to  the 
following  two  conditions:  (1)  This  device  may  not  cause  harmful 
interference,  and  (2)  This   device  must  accept  any  interference  received, 
including interference that may cause undesired operation.