10.  Calibration   
Position calibration is necessary for the first use of CM2 PRO or when calibration is not 
accurate in subsequent use.   
 
FreeView function. 
A visual screen which displays the detectable area of the receiver. 
Click or right click the system tray on the 
  icon .    On the pop-up
 
menu, click 
“Screen View” to display the detectable area of the receiver as shown below:- 
 
 
 
the receiver will continuously showing the projection image as shown above.    Adjust the 
distance  between  the  receiver  and  the  screen,  also  adjust  the  receiver's  angle  of 
elevation to make sure the projection image which shown by receiver can all be covered 
in the black area.   
 
Click "exit" to exit and get ready for Calibration. 
 
 
Auto Calibration (FreeCal) 
Click or right click the system tray on the 
  icon .    On the pop-up
 
menu -   
Click ”Calibrate (Auto)” to activate Auto Calibration.