Shenzhen DZH industrial Co. Ltd C201 Benutzerhandbuch
5
2.4
2.4
2.4
2.4 Pressure Curve of Key Strike
Point
Position(mm)
Initial
Position (mm)
After 10 millions (normal)
After 3 millions (fn)
After 3 millions (fn)
Force
(Mark)
Force (g)
Initial
Force (g)
After 10 millions (normal)
After 3 millions (fn)
After 10 millions (normal)
After 3 millions (fn)
1
S1 =0.9 ± 0.40
S1 =0.9 ± 0.60
PF
65 ± 20 g
(PF) 65 +20/-30 g
2
S2 =1.7 ± 0.40
S2 =1.7 ± 0.60
CL
P1(F)-P2(F)≧20 g
N/A
3
S6 =2.25± 0.30
S6 =2.25 ± 0.60
TM
Max 150 g
N/A
4
S3 =P2 ± 0.40
S3 =P2 ± 0.60
RF
Min 15 g
(RF) Min 10 g (normal key)
Min 5 g (fn key)
Min 5 g (fn key)
5
S4 = (N/A)
S4-- (N/A)
RP
RP/PF≧0.75
N/A
Fire
point
S5=P2+0.35/0.0
S5-- (N/A)
FP
F2~F2+15g
N/A
Mark statement:
PF=Peak force
CL=Click feeling, 點擊力
TM=Travel to make
RF=Return force, 返回力
RP= Return point (hysteresis)
FP= Fire point 擊發點
3、
、
、
、Function and Electronic Specifications
3.1 Function Specifications
Bluetooth Air-Link : 9 Meters (Straight Line without Obstacles)
Pairing Memory Switch: 3 Locations
Pairing Change Steps: After the power is off, select the Location of the Pairing Memory
Switch, and then back on.
Touchpad Resolution: 512 DPI
Rechargeable Battery Capacity: 370 mA/H
Battery Recharging Cycle Life: 500 Cycles @ 25℃
Battery Charge-Speed: 0.3C
Battery Operating Time: After charging is completed, more than 40 hours of continuous use.