Talgil Computing and Control LTD RF-MODULE-45 Benutzerhandbuch

Seite von 34
 
29
 
Wiring of Outputs and Inputs into the RTU BASE: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Plug-in unit of 2 outputs
 
Plug-in unit of 4 inputs
 
Locations for more  
Output Plug-in units
 
Locations for more  
Output Plug-in units
 
Locations for more  
Output Plug-in units
 
Each output  is 12v  2 
wired latching .  For 
normally open valves  
the  
RED
 wire goes to  
“Out-X” and the 
BLACK wire goes to  
“C” . For normally 
closed  valves,  
exchange between  the 
two wires
 
Each input  is 
connected by  2 wires . 
One wire goes to 
“In.X” and the other to 
“G” which is common 
to all the inputs. The 
polarity is of no 
importance
 
Each output  is 12v  2 
wired latching .  For 
normally open valves  
the  
RED
 wire goes to  
“Out-X” and the 
BLACK wire goes to  
“C” . For normally 
closed  valves,  
exchange between  the 
two wires
 
Each input  is 
connected by  2 wires . 
One wire goes to 
“In.X” and the other to 
“G” which is common 
to all  the inputs. The 
polarity is of no 
importance.  Bottom 
row is for inputs 1,3 
and upper row inputs 
2,4.