G7OPT Integrator Manual, DWI-00175 S1 R15
* a secure prompt will be shown, overwriting any other display, which indicates clearly that
the module is in removal-tampered mode; and
* the module and its companion UPC will no longer perform transactions normally – for
example, touchscreen functions will all be disabled.
– On a G7UPC:
* the module’s LEDs will flash red, alternating between on and off every half-second
* the module and its companion SDC will no longer perform transactions normally – for
example, PIN entry will be disabled.
• functional indications that the module has been destructively tampered:
– On a G7SDC:
* a secure prompt will be shown, overwriting any other display, which indicates clearly that
the module is in destructive-tampered mode; and
* the module and its companion UPC will no longer perform transactions normally.
– On a G7UPC:
* the module’s LEDs will flash red, alternating between on and off every quarter-second
* the module and its companion SDC will no longer perform transactions normally.
5.2.4.2.2 Attached Devices and/or Overlays
Check whether:
• the surfaces of the module’s various plastic parts do not line up as they should
• there are foreign devices attached to the module, including inside the cabinet
• you have a haunting feeling the module doesn’t look quite like as should.
5.2.4.3 Battery Replacement
5.2.4.3.1 Battery Type and Precautions
The backup battery is a 3.6V, 2400mAh, non-rechargable one.
It must be replaced by a trained
technician only.
The battery employs lithium thionyl chloride technology; its contents are toxic.
CAUTION: THERE IS A RISK OF EXPLOSION IF THE BATTERY IS REPLACED BY AN INCORRECT
TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
The battery must not be recharged, short-circuited or disassembled; hazardous-waste precautions must
be observed when disposing of it.
5.2.4.3.2 Procedure
The G7UPC includes a supercap which can provide power for long enough only to perform a graceful
shutdown when all other supplies are lost. If the external DC supply is disconnected, the supercap
has insufficient capacity to maintain power for long enough to replace the battery. During battery
replacement, therefore, the module’s DC supply should remain connected and turned on; otherwise
the backup supply will droop far enough to cause a destructive tamper.
During battery replacement it is not necessary to remove or even disconnect the module from the system
it is integrated with. This includes removal-tamper sensors; they can remain connected. One or more
external, analogue removal-tamper sensors will probably be triggered in the process but this is normal
when opening a system cabinet containing a G7 secure module. (Removal-tampering the G7UPC will
Chapter 5. Appendices