Maintenance 
 
6.5.8.2 
HPA PSU Mounting Shelf Installation 
 
The replacement HPA PSU mounting shelf should be installed in the following sequence: 
 
1.  Slide the replacement HPA PSU mounting shelf into the open slot on the right side of 
the HPA compartment frame. 
2.  Replace the three (3) 10-32 socket head cap screws (with #10 lock washers and flat 
washers) which secure the HPA PSU mounting shelf to the HPA compartment frame – 
see  Figure 6-12.
  A torque rating of 19.2 Inch Lbs. must be used to tighten the 
screws.
 
3.  Re-connect the ground conductor to the HPA PSU mounting shelf rear panel 1/4-20 
GND terminal – see Figure 6-14
4.  Re-connect the two (2) return conductors to the HPA PSU mounting shelf rear panel 
1/4-20 RTN terminals – see Figure 6-14. 
5.  Re-connect the two (2) positive conductors to the HPA PSU mounting shelf rear panel 
1/4-20 POS terminals – see Figure 6-14
6.  Replace the plastic cover, which shields the POS and RTN DC output terminals – see 
7.  Re-connect the serial cables (
SX03-10924-02 and SX03-10924-01
) to the HPA PSU 
mounting shelf rear panel serial connectors J1 and J2 respectively – see Figure 6-14. 
8.  Re-connect the 6-pin pluggable AC terminal block to the HPA PSU mounting shelf rear 
panel 6-pin AC terminal block receptacle – see Figure 6-14. 
9.  Install the rectifier modules in the HPA PSU mounting shelf - see section 6.5.7.2
10. Switch ON the HPA PSU circuit breakers, located on the HB cabinet PDU or LB cabinet 
PDU – please refer to section 2.3.4 or 2.3.5 for breaker designations. 
11. Using the HBE GUI, place the HB sub-system in broadcast mode or, using the LBE 
GUI, place the LB sub-system in transmit_only mode. 
12. Close the HPA compartment front and rear doors. 
13. Close the electronics compartment front door. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 