X75 SERIES - Mk3 Controller
INSTALLATION & OPERATING MANUAL
Manual No. x75mk3-11
x75-man-Rev11-0815.indd
6.4
Safety
The X75 system is compliant with UL60950-1, EN60950-1, CSA22.2-60950-1 and
all other derivatives of the core IEC60950-1 standard 2nd Edition when installed
correctly within a restricted access environment.
The X75 system is CE marked to indicate conformance to the European Union’s
Low Voltage and EMC Directives.
6.5
EMC
The X75 complies with the following Norms when correctly installed.
Conducted Emissions:
EN55022, level A
Radiated Emissions:
EN55022, level A
ESD:
EN61000-4-2, level 4, criterion A - 8kV contact, 15kV
air.
Radiated Immunity:
EN61000-4-3, level 3, criterion A - 10V/m.
Surges (power ports):
EN61000-4-5, level 1, criterion A - 500V
6.6
Environmental
Operating Temperature:
-20°C to 70°C, derating 2.5%/°C from 50°C to 70°C
Storage Temperature:
-40°C to 75°C
Humidity:
0% to 95% Non-Condensing
6.7
Physical Specification
Case Material:
Steel
Finish:
Clear Passivated
Dimensions:
1.72H (43.7) x 17.2W(437) x 14.47D(368)
Rack Width:
19” or 23” using dual purpose kit supplied.
NOTE: Mid-mount is recommended when used in
free space.