X75 SERIES - Mk3 Controller
INSTALLATION & OPERATING MANUAL
Manual No. x75mk3-11
x75-man-Rev11-0815.indd
6.4
Safety
 
The X75 system is compliant with UL60950-1, EN60950-1, CSA22.2-60950-1 and 
all other derivatives of the core IEC60950-1 standard 2nd Edition when installed 
correctly within a restricted access environment.
 
The X75 system is CE marked to indicate conformance to the European Union’s 
Low Voltage and EMC Directives.
6.5
EMC
 
The X75 complies with the following Norms when correctly installed.
 
Conducted Emissions: 
EN55022, level A 
 
Radiated Emissions: 
EN55022, level A
 
ESD: 
EN61000-4-2, level 4, criterion A - 8kV contact, 15kV 
air.
 
Radiated Immunity: 
EN61000-4-3, level 3, criterion A - 10V/m.
 
Surges (power ports): 
EN61000-4-5, level 1, criterion A - 500V
6.6
Environmental  
 
Operating Temperature: 
-20°C to 70°C, derating 2.5%/°C from 50°C to 70°C
 
Storage Temperature: 
-40°C to 75°C
 
Humidity: 
0% to 95% Non-Condensing
6.7
Physical Specification
 
Case Material: 
Steel
 
Finish: 
Clear Passivated
 
Dimensions: 
1.72H (43.7) x 17.2W(437) x 14.47D(368)
 
Rack Width: 
19” or 23” using dual purpose kit supplied.
 
 
NOTE: Mid-mount is recommended when used in 