Tramigo Ltd T-1304 Benutzerhandbuch

Seite von 78
 
 
 
 
  47 
 
6.2.25  
Output 
Command:  
 
output,portId,type,commandName,1/0,
time
 
Alias:    
 
none 
Parameters:    
portId – Output port ID number 
Type – The type of the output port 
commandName – The command name for output 
1/0 – High or low output 
Time – The duration output is on or off 
 
Description:    
Configure T23 output ports to send signal for accessories 
Related Cmds: 
None 
Security:  
 
Owner 
Message Format:  
Command Response 
Notes:  
1.  Port Ids are from 1-2. 
2.  Types can be IMMOBILIZER or GENERAL. 
 
Errors: 
1.  Parameter error 
Examples:  
 
OUTPUT,1,IMMOBILIZER,DISABLE,1,0 
Tramigo: Output: 1, type: immobilizer, literal: disable, high: 1, time: 0, 15:37:33 Dec 12 
 
DISABLE,ON 
Tramigo: Disable, vehicle ignition disabled, parked, at Valero Street-Rufino Street, 
Makati, NCR, PH, 14.55931, 121.01934, 15:39:06 Dec 12 
 
 
Custom output command: 
 
OUTPUT,2,GENERAL,LIGHTON,1,1000 
Tramigo: Output: 2, type: general, literal: LIGHTON, high: 1, time: 1000, 15:40:03 Dec 
12 
 
LIGHTON 
Tramigo: Output (LIGHTON), turned on for 1000 milliseconds, 15:40:19 Dec 12 
 
 
Check output port current settings: 
 
OUTPUT,2 
Tramigo: Output: 2, type: general, literal: LIGHTON, high: 1, time: 1000, 15:42:06 Dec 
12