6.2.40  
Temperature  
Command:  
 
Temperature,on/off/
value
 
Alias:    
 
TEMP 
Parameters:  
on/off - turns on or off temperature reporting 
 
value
 – optional. Temperature limit 
 
Description:
  
Sets the MCU temperature reporting on or off, or set the temperature limit 
Related Cmds: 
none 
Security:  
 
Friend  
Message Format:  
Command Response 
Notes:  
1.  Can be used to monitor unit temperature. 
2.  Temperature report occurs immediately when the internal temperature of the unit exceeds 
the limit.  
3.  Temperature limits value from 30 C to 100 C, default value is 70 C. 
 
Errors:  
 
1.  Parameter Error  
 
Examples:  
 
TEMPERATURE 
TRAMIGO: temperature, limit 70 C, reporting is turned on, 03:43 Oct 23 
 
TEMP,off 
TRAMIGO: Temperature, reporting is turned off, 03:42 Oct 23 
 
TEMP,100 
TRAMIGO: temperature, limit 100 C, reporting is turned on, 03:45 Oct 23