Tramigo Ltd T-1304 Benutzerhandbuch

Seite von 78
 
 
 
 
  72 
 
8  T23 Fleet Parameters 
 
T23 Fleet parameter defaults are changed with the 
SET
 command and displayed with the 
GET
 
command. 
 
Boolean units are 1 for on and 0 for off. 
 
Important:
 Changing the parameters can greatly impact the behaviour of the unit, so only 
advanced users should change the default values. Use the DBG, CFG, DEFAULT command to 
return all the parameters back to the factory defaults. 
 
Name 
Default 
Min Val 
Max 
Val 
Units 
Comment 
AutoRearmTime 
30 
  
Delay before arming again 
CallTimeOut 
9999 
min 
timeout when device is calling a user 
DisableDelay 
45 
60 
Immobilization delay 
DisablePowerButton 
boolean 
Disable power button 
DisableShockSensor 
boolean 
Disable shock sensor 
HFMaxTimeBetweenPress 
1000 
9999 
ms 
Maximum break between two HF button presses (for 
GPIO input) 
HFMinPressTime 
200 
9999 
ms 
Minimum time to recognize a HF button press (for 
GPIO input) 
HFMinTimeBetweenPress 
200 
9999 
ms 
Minimum break between two HF button presses (for 
GPIO input) 
IgnitionInputGPIO 
boolean 
Use GPIO input as the ignition input 
IgnitionInputShock 
boolean 
Use shock sensor as the ignition input 
IgnitionOff 
boolean 
Enables Ignition off reporting 
IgnitionOn 
boolean 
Enables Ignition on reporting 
IgnitionOnAvgSpeed 
30 
999 
km/h 
Minimum average speed to prevent ignition off (applies 
only to shock/ignition detection) 
IgnitionOnMaxSpeed 
30 
30 
999 
km/h 
Maximum speed max-min difference to prevent ignition 
off (applies only to shock/ignition detection) 
LoudSpeakerVolume 
  
Loud speaker volume 
MaxAccel 
15000 
99999 
mm/s^2 
Maximum accepted acceleration 
MaxDistanceAtLocation 
50 
999 
Maximum distance from a landmark to report "at 
location" 
MaxFixAge 
60 
minutes 
Time delay to show old position in SMS reports 
MaxSpeed 
200 
999 
km/h 
Maximum accepted speed (otherwise the fix is 
interpreted as invalid) 
MicrophoneGain 
10 
  
Low is 1 highest is 10 
MinTripDistance 
300 
  
999 
Minimum trip distance 
MovingSpeed 
  
999 
km/h 
Speed threshold to decide if the vehicle is moving or 
stopped 
NavLogStopLimit 
30000 
optimum 
value 
set 
  
  
Limit of file space used for navigation logs 
NoSleepCharge 
optimum 
value 
set 
  
boolean 
Don't go to sleep if the battery is being charged 
NoSleepDisabled 
600 
boolean 
Don't go to sleep if the vehicle is immobilized