TWS-02 Operation 
IMPORTANT NOTICE TO USER:  The installation of any temperature or water detection or automatic 
water shut off system does NOT guarantee a temperature condition or actual water will be detected on 
all occasions or circumstances.  Due to the variety of environments the system can be installed, how it is 
maintained  and  types  of  installation,  Vital  Home  Systems  does  NOT  guarantee  or  warrant  against
 
temperature or water or property damage as a result of or/with the use of this system.
 
Normal Operation 
The TWS-02 senses both temperature and water in the same device.  The TWS-02 senses ambient room 
temperature and alarms when a set temperature band reaches an “out of band” condition.  The TWS-02 
also senses water via water probes on the bottom of the case and via an external water sensing probe.  
The TWS is paired with the VHS 1060 control panel and may also be paired with the VHS VC100.  If the 
1060 control panel loses connection with the TWS-02 after 12 hours it will send a “Fault Detected” report 
with the sensor ID to the user.  The TWS-02 will also send a report on the condition of a low battery. 
Temperature Detection 
The TWS-02 will monitor temperature and report temperature when queried by the 1060.  The TWS-02 
can also have a temperature band set with a high and low temp band set by the 1060 setup software.  
Whenever the TWS-02 is above the high temperature setting it will alarm and whenever the TWS-02 is 
below the Low Temp Band setting it will alarm and notify the 1060 Control Panel with a Sensor Zone ID.  
If a VC100 is paired with the 1060 and TWS the VC100 will close on a Low Temp Alarm.  The VC100 does 
not close on a high temp alarm. 
Water Detection 
The  TWS-02  will  only  detect  puddling  water  when  it  contact  the  water  probes.    It  does  not  detect 
humidity.  Water  MUST  contact  the  probes  to  actually  report  water.  When  water  is  detected  and 
contacts the probe, the TWS-02 sends a “Leak Detected” report with the Sensor Zone ID. The TWS-02 
will also make a beeping noise to alert the user.  If the sensor is picked up and loses contact with the 
water or the alarm clears the TWS-02 will send an “Alarm Ended” report to the control panel. If a VC100 
valve controller is paired with the 1050/1060 control panel and a specific TWS-02, it will be commanded 
to close upon the detection of water and will not reopen until the VC100 is commanded to open on the 
VC100, the 1050/1060 or remotely. 
 
External Water Probe 
To install the External water probe.  Plug the jack into the right side of the TWS-02.  The TWS-02 will now 
sense water in two locations at the same time.  If possible affix the external probe to the surface to be 
monitored with 2 screws. You may also use double stick tape BUT only use thin film tape that does not 
raise the external probes more than 2 millimetres off the surface. 
DO NOT USE FOAM DOUBLE STICK 
TAPE this increases the distance from the probe to the surface of the water you are trying to detect.  
Accidental  disconnect  of  the  external  probe  will  disable  water  detection  by  the  external  probe.  The 
external probe does not detect temperature only water.