5. Re-install the circuit board in to the plastic
housing.
6. Connect the buss cable to J4 terminal
header on the UM-ZW. Refer to control
panel installation manual for cable
requirements.
panel installation manual for cable
requirements.
7. Install J3 TERM link if required. Refer to
xGen Installation & Programming Guide.
8. Turn on the power to the control panel and
wait for panel to complete initialisation.
9. The LED next to the ENROLL switch will
blink three times each second to indicate it
is not learnt in. Push and hold the
ENROLL switch on the xGen panel for 3
seconds to perform enrollment.
is not learnt in. Push and hold the
ENROLL switch on the xGen panel for 3
seconds to perform enrollment.
10. The LED next to the ENROLL switch will
blink once per second to indicate it is
learnt in.
learnt in.
UM-ZW Device Programming
Programming is performed via the xGen
control panel.
1. Log in to the xGen control panel.
2. Click Advanced – Devices – System
control panel.
1. Log in to the xGen control panel.
2. Click Advanced – Devices – System
Devices – Relay Expanders.
3. Select the UM-ZW device number from
the drop down box:
4. Click Expander Name to set the module
name. The default is “Z-Wave Expander”.
5. Click Save to save changes.
6. Click Back.
7. Click Expander Options.
8. If tamper is required, tick Tamper Enable.
9. Click Save to save changes.
10. Re-install the front plastic housing taking
6. Click Back.
7. Click Expander Options.
8. If tamper is required, tick Tamper Enable.
9. Click Save to save changes.
10. Re-install the front plastic housing taking
care with the internal tamper switch, then
tighten the bottom screw.
tighten the bottom screw.
Adding Z-Wave Devices
1. Log in to the xGen control panel.
2. Click Settings.
2. Click Settings.