5.7  Restoring to Factory Default IP Address and Password 
This section describes how to restore your HaulPass V10g to the factory default IP address and password. Two 
alternative methods are available: manual process and GUI process. 
Manual Process 
This process is most easily accomplished at a desk, but can also be completed at the installed location. 
Note:  Restoring factory defaults will set all user accounts back to the factory settings. Any stored 
passwords and/or accounts will be reset. 
First, connect the “POE Injector Out” to Port 1 of the V10g (black cable in photo below) and connect the “POE 
Injector In” to Port 2 of the V10g. This creates a loopback through the POE. Note that this procedure cannot be 
completed through a switch. Once configured as shown in Figure 12, power cycle the V10g by power cycling the 
POE injector. 
 
Figure 12. Restoring the V10g to Factory Default IP Address and Password 
Wait a full three minutes. Then, without powering down, take the blue cable (the cable that was feeding Port 2) and 
connect it directly to a PC. At this point the IP address will be 192.168.66.2. 
 
The login will now be “admin” with no password. You can now change the IP address and other network settings. 
Once complete, save your settings twice when on the relevant page and also in Maintenance > Configuration >Save 
startup-config. Note that once you change the IP address, you will need to login again with the new IP address 
before you can save the configuration. During this time, do not shut off power.