TE Connectivity Germany GmbH ARISOTX Benutzerhandbuch

Seite von 17
 
 
Data Sheet 
 
ARISO M30 GPIO 
116-19004 Rev. A3 
21 January 2014 
    
Rev 6 
 
 
 
3 
of
 17 
 
 
 
 
 
1. 
PRODUCT PART NUMBERS, MARKING AND LABELING 
1.1 
Product marking and labeling 
  Product name 
ARISO 12 Watt 
  Identification number 
TXM030S012PNP2A / RXM030S012PNP2A 
o  Tx / Rx 
Transmitter / Receiver 
o  M 
Form factor, M = Circular 
o  030 
Diameter 
o  S 
Product type, S = Standard  
o  012 
Power level, 12W 
o  PNP 
Data type, PnP variant 
o  2/8 
Number of PNP channels 
o  a/b 
Coding option 
 
 
1.2 
Part number 
  2287598-1: ARISO TXM030S012PNP2A 
  2287598-3: ARISO TXM030S012PNP8A 
 
  2287598-2: ARISO RXM030S012PNP2A 
  2247598-4: ARISO RXM030S012PNP8A 
  2247598-5: ARISO RXM030S012PNP8B 
 
 
2. 
GENERAL 
2.1 
Design and Construction 
 
Product shall be of the design, construction and physical dimensions specified on the applicable customer product 
drawing (C-2287598) and product specification (108-19484). 
 
The following variants are available.   
 
  M30, 4 pos variant, 2 PNP Channels: 
o  ARISO TXM030S012PNP2A M30 Power Transmitter / Data Receiver.  
o  ARISO RXM030S012PNP2A M30 Power Receiver / Data Transmitter. 
 
  M30, 12 pos variants, 8 PNP Channels 
o  ARISO TXM030S012PNP8A Power Transmitter / Data Receiver. 
o  ARISO RXM030S012PNP8A Power Receiver / Data Transmitter. 
Optimized for connection to distribution boxes 2273161-1 (S1 only), 273146-1, 2273139-1 and 
2273134-1. 
o  ARISO RXM030S012PNP8B Power Receiver / Data Transmitter. 
Optimized for connection to distribution box 2273161-1 (S2 supported at sockets 1 and 2, sockets 7 
and 8 not connected). 
 
2.2 
Features 
 
The product has the following features: 
 
  Power input reverse polarity protection: 
The product switches off in case the power connected to the Tx has wrong polarity. 
  Power output short circuit protection/ Data output short circuit protection:  
The product switches off the power / data in case the outputs are short circuited or in case the load is 
above specification. 
  Data input / output reverse polarity protection: 
The product is protected against reversed connections of the data inputs and data outputs. 
  Over-temperature protection: 
The product switches off in case the temperature becomes too high.