WaveLynx Technologies Corporation WLTC-DHMM-1K15 Benutzerhandbuch

Seite von 1
 
 
 
 
 
 
 
–– 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Max Length to Panel 
Length 
AWG 
200’ (60 m) 
22 
300’ 
20 
500’ 
18 
Common Cable Connections 
Red 
Power In 
Black 
Ground 
Shield 
Shield Ground 
Brown* 
Tamper Out 
Green 
Wiegand Data 0 / RS 485A 
White 
Wiegand Data 1 / RS 485B 
Yellow* 
Beeper Control 
Blue* 
Green LED Control 
Orange* 
Red LED Control 
Current @ 12 V and 25 C 
Avg. mA 
Max. mA 
110 
160 
Current for ET25 @ 12 V and 25 C 
Avg. mA 
Max. mA 
140 
190 
Install the Reader Screw 
Install the #4-40 screw or pin-in-torx at the bottom of the 
reader.  
Test the Reader 
Power the reader, the red light-bar will light, followed by a 
beep. Present a valid credential to the reader and the  
light-bar will turn green. 
 
Attach the Reader to the Wall plate  
Align the reader so that the tabs of the base plate slide into 
the slots on the wall plate and slide the reader into position.  
 
Wall Mounted Reader Installation 
This installation guide applies to the following types of readers: 
 
 
 
 
 
 
  ET20 – Single Gang Reader 
  ET25 – Single Gang Reader with Keypad 
Included: 
  (2) #6 Screws 
  Reader, Backplate, and Wall Plate 
The Following tools will needed to install  
a wall mount reader: 
  Phillips Screwdriver 
  1” (25mm), 1/8” drill bits 
  T8 Security Torx Bit (optional for increased tamper detection) 
 
Install Metal Wall Plate to Single Gang Box 
Connect the wall plate to the single gang box using the provided #6 screws. Alternatively you can use the provided #4 screws in 
the four outer holes for other installation requirements. Drywall installations will require molly bolts.   
 
Wire the Cable to the Control Panel 
 
Screw or 
pin-in-
torx 
Contact Us 
WaveLynx Technologies 
(303) 327-1477 
www.wavelynxtech.com 
 
Alternative for 
situations 
outside of a 
single gang box 
installation.  
Standard Single 
Gang Box 
Installation 
*these wires are only used in 
Wiegand readers.   
*Patent Pending 
This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions:  (1)  this device may not cause harmful interference, and 
(2)  this device must accept any interference received, including interference that may cause undesired operation. 
Changes or modifications not expressly approved by 
WaveLynx could void the user's authority to operate the equipment.
 
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause 
interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
 Le présent appareil est conforme aux 
CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de 
brouillage, et (2) l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
 
 
(1) #4-40, (1) pin-in-torx
 