TC Installations TCENC201 Merkblatt

Seite von 1
 
 
18-11-08 
Page 1 of 1 
TC Installations Limited 
Units 11 – 13 Highlode Industrial Estate, Stocking Fen Road, Ramsey, Cambridgeshire. PE26 2RB. 
Tele: +44 (0) 1487 710555 
FAX: +44 (0) 1487 710060 
 
 
 
 
 
Part No: TCENC201 
• 
Flameproof  
• 
ATEX II 2GD EEx d IIC T6/T5  
• 
Operating Temp. Range -10°C to +50°C IP66   
• 
II 2 GD EExd IIC T5/T6 @Ta55°C IP66 T85°C or T100°C 
 
 
 
 
 
The iWAP100 has been developed to deploy ethernet 
networks wirelessly in hazardous areas. Two increased 
safety omni-directional high performance antennas are 
used, meaning coverage is greatly enhanced. They can 
be mounted locally on the enclosure using the brackets 
supplied or on a wall away from the iWAP100 
electronics enclosure so they can be mounted in the 
optimum position for best coverage of the area.  
 
The iWAP100 is available in many versions and can be 
supplied with industry leading wireless network 
manufacturers hardware such as Symbol AP5131 or 
Cisco Systems AP1200 Access Points for direct 
connection to ethernet hubs or switches) or the Symbol 
AP300 Access Port (for connection to a Symbol 
wireless switch) Network speed is up to 54Mbps and 
compliant with IEEE 802.11a, b, g and is WiFi 
certified. 
Connection back to the safe area server is via your own 
IT infrastructure by either CAT5E / STP cable or fibre 
optic cables.  
 
If the WLAN is outside and the antennas are at risk of 
lighting strikes surge suppressors can be built in to 
protect your network hardware. Also a heater can be 
installed to ensure that condensation or cold is not a 
problem in installations subjected to cold and high 
humidity.  
 
Complete systems including site surveys and 
commissioning are available from T C Installations 
Limited. 
 
 Technical Data:
 
Component
 
iWAP 100
 
Supply Voltage
 
24v DC or 110-230v AC or power over ethernet (POE) (note heater and fibre 
options not possible with POE) 
Material
 
Grade LM6 cast alloy with epoxy coating 
Mounting
 
Wall or any flat surface using 4 bolts/screws 
Cable entry
 
Bottom face 2 x M20 & 1 x M25 for data and power connections. Right and left 
side, 1 x M20 for connection of antenna. Threaded gland entries are for use 
with certified ATEX Exd glands.  
Radio Network
 
Network hardware dependant - 802.11a,b,g compliant, 54Mbit/s on 2.4 & 5GHz 
Interface
 
iWAP100-4 : RS232, RS422 and RS485 
Weight
 
Approx 14 Kg depending on version 
Ambient Temperature
 
-10°C to +50°C (-20°C to +55°C on request) 
Dimensions
 
280mm x 276mm x 214mm (WxHxD) 
IP Rating
 
IP66 
Certification Type
 
II 2 GD EExd IIC T5/T6 @Ta55°C IP66 T85°C or T100°C 
Certification Number
 
DEMKO 03 ATEX 136110