APPI Technology SAS BSAPC2U01 Benutzerhandbuch

Seite von 56
 
APPI-Com V3.0 – Copy prohibited
 
 
 
www.appi-technology.com 
 
APPI-Com
LR
 Full-Duplex Hands-Free 
VoiceCom system
 
 
CE MODELS: BS-APC2-0x and BS-APC2-Ax 
FCC/IC MODELS: BS-APC2U-0x/Bx 
Singapore MODELS: BS-APC2S-0x/Bx 
 
USER’s MANUAL 
Version 3.0 
Introduction : Thank you for choosing APPI-Com ! 
The  APPI-Com
LR
  kit  (“Long  Range  Series,  from  Rev.  2.0)  allows  communication  in  a  "hands  free  & 
conference  mode”  over  several  free-band  channels  for  the  mobile  team  members.  No  "Base",  Relay  or 
"Master unit": thanks to the Syncall® Technology (exclusive patent), 
the signal loss of any  of the kit43’s 
module  does  not  affect  the  communication  between  the  others
,  and  the  “lost”  one  can  return  at  any 
time into the dialogue: a guarantee of safety and efficiency for the team!  
 
The modules of a kit should be set to the same channel to communicate: the kit establishes a full-duplex 
dialogue on any of the 16 available channels (US Version), allowing the simultaneous use of several kits in 
the same area. 
 
Several  usages  are  possible:  the  “natural”  TALK  mode  allows  full-duplex  conversation  while  the  LISTEN 
mode  enables  listen to the  team members  but  not participate to the  conversation.  Each module can be 
used interchangeably in "Talk" or in "Listen".  The  MULTIplex  configuration allows  create teams of more 
than 3 members: in this case, the “priority” pair can have a full-duplex hands-free conversation while any 
other team member can intervene, only one at a time, to ensure that only one conversation takes place on 
the used channel. 
 
APPI-Com modules are IP66 certified (dust and water) and use frequencies set in the ISM free bands (CE or 
FCC/IC  certified).  The  use  of  APPI-Com  in  several  countries  could  be  restricted:  users  must  comply  with 
standards in the country of use. 
 
 
ATEX Version (Atmosphere EXplosive): model BS-APC2-Ax 
The 
ATEX
  version  of  the  device  is  different  from  the  standard  one:  one  can  clearly  identify  it  with  it 
special front side marked with the ATEX symbol  
 
ATEX certification class: 
CE 
 II 3G/D Eex is T6 IP67 
 ATEX certification: usage limitations & compliance with ATEX regulation 
1.  Usage temperature limits : -10°C à +60°C 
2.  Authorized for use 
in a zone 2
 (GAS) and 
zone 22 
(DUST) 
3.  Authorized for use with the provided ATEX Audio accessory, exclusively. 
4.  Authorized for use with the provided rubber cover, exclusively. 
5.  Authorized for use with the provided internal or pre-fitted external antenna, exclusively. 
6.  Prohibited to connect or disconnect device peripherals in a zone 2 or 22. 
7.  Prohibited to remove the pre-fitted external antenna in a zone 2 or 22.  
8.  Prohibited to remove the rubber cover in a zone 2 or 22. 
9.  Prohibited  to  use  the  device  in  a  zone  1  or  21  and  a  zone  0  or  20,  or  if  the  plastic  case  is 
defective. 
10. Prohibited to charge the battery in a zone 0, 1 or 2 and zone 20, 21 or 22.