SALUS North America Inc. SS912ZB Benutzerhandbuch

Seite von 2
Version 3
Installation/Quick Start Guide: Slim Door/Window Sensor (SS912ZB)
Visit www.salusinc.com for the User Manual
 
In the Box
Tools Needed
 Note:
 
 Additional  equipment  may  be  required
due to building construction or materials,
or  other  radio  interference  that  may
reduce the radio range.
Sensor with battery
(1x CR2, 3V Lithium)
Magnet
Mounting Kit
Installation/
Quick-start Guide
#1 Phillips Screwdriver
P
AIRING
I
NSTRUCTIONS
• 
Follow your system’s instructions to prepare to add devices to the system. 
• 
Remove the face plate from the Sensor and pull the battery tab to start 
the pairing process. 
• 
When the Sensor is detected and added to the system, proceed to the 
Sensor installation. 
I
NSTALLATION
I
NSTRUCTION
• 
Identify the location for the Sensor and Magnet, orienting the flat end of 
the Sensor and Magnet parallel to each other as shown, and the 
Magnet on the right side (side with indicator). The preferred location 
for the Sensor is on the door or window casing on the handle side of 
the door or window, with the Magnet on the door or window as close as 
possible to the Sensor. Proper installation may require mounting the 
Sensor and Magnet inverted or rotated from the orientation shown. 
• 
Position the Sensor at the desired location and screw into position 
using the screws provided. If screws are not appropriate, use the included 
adhesive pad by first removing the brown backing of the adhesive pad 
and attaching it to the Sensor bottom. Make sure to properly align the 
tamper switch opening. Then remove the white/red paper tape and press 
the Sensor to the desired location. (For UL installations, the unit must 
be mounted with screws.) 
• 
Open the Magnet case, position the Magnet at the desired location and 
attach to the door or window with the screws, replacing the Magnet cover 
when done. If screws are not appropriate, use the adhesive pad by first 
removing the brown backing and attaching it to the Magnet bottom. Then 
remove the white/red paper tape and press the Magnet to the desired 
location. (For UL installations, the unit must be mounted with screws.) 
Depending on the depth of the door or window in the frame, the included 
spacer may be required to raise the Magnet above the surface of the door or 
window. Use the longer screws to attach the Magnet with the spacer. 
• 
Open and close the door to verify that the Sensor is working properly, and 
the Sensor or Magnet does not interfere with the opening and closing of the 
door. 
R
EPLACING THE
B
ATTERY
(Use only Duracell DL-CR2, Rayovac RL-CR2, Energizer EL1CR2, or GP Batteries GPCR2 batteries) 
• 
Slide the Sensor face plate up and lift it from the Sensor body.  
• 
Press a finger on the positive end of the battery and lift to remove the battery 
from the Sensor. 
• 
Insert a new battery into the Sensor, observing the proper polarity.  
• 
Position the Sensor face plate over the Sensor body and slide the face plate onto 
the Body. 
F
ACTORY
R
ESETTING THE
S
ENSOR
• 
Remove the face plate from the Sensor. 
• 
Remove the battery. 
• 
Press and hold the tamper switch while re-inserting the battery. 
• 
Release the tamper switch when the LED lights on the front of the Sensor. The 
Sensor is reset to factory defaults and will respond to pairing requests. 
• 
After pairing, replace the face plate on the Sensor. 
LED
I
NDICATIONS
Solid at power up: 
Initializing, checking for Factory Reset 
3 flashes then pause: 
Searching for network to join