8.11.2  Installing Display G & E and the external antenna 
This  can  be  installed  inside  a  chamber  or,  because  it  is  watertight,  on  the  outside  in  a  protective 
casing  or  in  a  building.  The  device  shall  be  positioned  according  to  site  accessibility  and  the 
surrounding environmental conditions. For countries with a harsh winter climate, it is best to place 
the device underground (deep enough to be protected from the cold) or in a building. 
According to the type of installation envisaged, several types of aerial are available. It is essential to 
make a careful installation method in order to guarantee good data transmission subsequently. The 
quality of the signal level (value from 0 to 31) must be verified for each site, and the measured value 
must  be  greater  than  7  for  data  transmission  by  SMS,  or  greater  than  12  if  data  is  being  sent  via 
GPRS. 
 
There are three possible aerial installation cases: 
Aerial outside in a protective casing: 
This type of installation has the major advantage of providing a high signal level, ensuring better data 
transmission. The aerial can also be positioned on a mast or pole near the port, whilst installing the 
HydrINS display logger inside the port. 
Aerial in a port/valve chamber:  
This  installation  can  be  created  with  a  half-wave  aerial  or  a  dipole  aerial,  because  both  have  a 
magnetic base. Because each site has different characteristics, a signal level test must be carried out 
with the port closed. In the event of a negative result, try a different aerial position. 
 
 
 
 
 
:  An  aerial  can  also  be  placed  under  the  cast  iron  plate,  but 
remember that there is a risk of knocking the aerial off each time the 
port  is  opened.  This  installation  is  recommended  for  occasional 
measurements.