Valeport Ltd 0804IDU Benutzerhandbuch

Seite von 83
 
HydrINS 2 / HydrINS 2 Mini flow meter  
Installation Manual  
 
Page 58 / 83 
9.2  Display units 
Display A
 
Outputs
 
Two  pulse  outputs,  opto-isolated  open  collectors. 
Maximum frequency: 50 Hz Pulse width: 10ms  - 28V 
50  mA  maximum  -  Max.  impedance  35  Ohms  - 
Typical capacitance: 25 pF 
 
Two  alarm  outputs:  Pulse  width:  10ms  -  28V  50  mA 
maximum  -  Max.  impedance  75  Ohms  -  Typical 
capacitance: 10 pF 
 
 
LCD screen: Timed or continuous backlit, two lines of 
16 characters 
Magnetic switch control. 
Display:  mean  speed,  real-time  flow  rate,  positive  - 
negative - net totalizer, alarms. 
Alarms:  Two  dry  contacts  Programmable  using 
Winfluid software via RS 232 
Alarm  type:  Absence  of  water,  sensor  error,  low 
battery, higher or lower flow rate, power supply error, 
HydrINS not connected. 
Connection:  5-metre  cable  supplied  to  connect  the 
display to the HydrINS 2
®
Max. length: 200 m. 
Communication:  Probe  and  display  programmed  via 
RS 232. 
Firmware  updated  via  RS  232.  Interfaced  with 
Winfluid. 
Waterproofing:  IP68/NEMA6  under  2  metres  of  water 
(with fittings connected) for 72 hours 
Dimensions
:
 154 mm / 248 mm / 56 mm. 
Weight: 1 kg. 
Guarantee: 36 months.
 
Electrical power
 
3.6 V - 38 A/h internal lithium batteries.
 
Battery  life:  4  to  10  years  according  to  the  options 
chosen.
 
Possible  power  supply  via  external  batteries  or  DC 
power supply (optional)
 
Battery compartment isolated from the electronics.
 
Display C
 
Outputs
 
Four  pulse  outputs,  opto-isolated  open  collectors. 
Maximum frequency: 50 Hz Pulse width: 10ms  - 28V 
50  mA  maximum  -  Max.  impedance  35  Ohms  - 
Typical capacitance: 25 pF 
Two  active  4-20mA  outputs  with  common  negative 
connection.  1  Kohm  maximum  loop  resistance  (20  V 
at 20 mA). 
Two  alarm  outputs:  Pulse  width:  10ms  -  28V  50  mA 
maximum  -  Max.  impedance  75  Ohms  -  Typical 
capacitance: 10 pF 
Electrical power
 
DC  power  supply  =  20  -  36V  DC,  with  polarity 
reversal protection (20V - 28V DC for Serial Numbers 
below 41574)
 
Display with 
recorder
 
Outputs
 
Two  pulse  outputs,  opto-isolated  open  collectors. 
Maximum frequency: 50 Hz Pulse width: 10ms  - 28V 
50  mA  maximum  -  Max.  impedance  35  Ohms  - 
Typical capacitance: 25 pF 
Two  alarm  outputs:  Pulse  width:  10ms  -  28V  50  mA 
maximum  -  Max.  impedance  75  Ohms  -  Typical 
capacitance: 10 pF  
RS232 communication output (optional Bluetooth) 
Electrical power 
 
On 3.6 V / 57 Ah lithium batteries, internal battery 
with standard 3-year battery life, with one reading 
every 15 minutes and 1 sms/day. 
 
Communication
 
Data sent via SMS or GPRS.