Enermax Revolution87+ 1000W ERV1000EWT-G Benutzerhandbuch

Produktcode
ERV1000EWT-G
Seite von 3
 www.enermax.com   forum.enermax.com
1200
2000
1800
1600
1400
1200
1000
800
600
400
200
0
25
50
75
10
0
%
FAN RPM (±10%)
PSU Loading (@25°C ambient)
Others
REVOLUTION87+
550/750W
REVOLUTION87+
650/850/1000W
SpeedGuard
87PLUS ready!
 (Max. 93% @ 230VAC)
93
91
89
87
85
20%
50%
100%
%
High efficiency standard & ECO design.
PSU Loading
230VAC
115VAC
PSU Ef
ficiency
100%
75%
50%
25%
20
o
C
30
o
C
40
o
C
50
o
C
Temperature
Rated Output
High efficiency performance certified to meet 
80 PLUS
®
 GOLD requirements.
Advanced fuzzy logic fan speed control for optimal cooling and 
minimum noise. (Patented)
Future ready!
24/7 @ 50
o
C ready!
HeatGuard
CordGuard
SafeGuard
Non-stop industrial-class performance 
at 50°C ambient.
Keeping PSU fan running for 30-60 seconds 
after shutdown to dissipate the remaining 
system heat and prolonging system lifetime.
Fixing the AC cord tightly to avoid 
accidental shutdowns of your PC.
Industry-leading multiple protection circuitry of 
OCP, OVP, UVP, OPP, OTP, SCP & SIP.
ENERMAX
Others
12P socket design for possibly upcoming
      10P & 12P connector generations.
300
550
1000
Twister bearing fan inside!
World’s leading industrial fan.
A
B
C
Lower noise:1-2db(A) decrease
Longer life:100,000 hours MTBF
A. Minimal contact area
     For effective noise reduction
B. Rotor with integrated magnet
    For  frictionless and smooth motion
C. Self-lubricating bearing material
    Abrasion protection for longer lifetime
ErP Lot 6 2010 ready!
Advanced +5Vsb circuitry with up to 20% improved 
efficiency in comparison with generic designs helps 
your system meet ErP Lot 6 2010 (AC < 1W at standby) 
requirement.
*With ErP Lot 6 enabled motherboard. 
20
40
60
10
30
50
%
36%
57%
Non ErP Lot 6 
2010 Compliant PSU
ENERMAX ErP Lot 6 
2010 Compliant PSU
Intel suggests >50%
PSU +5Vsb efficiency @ 0.09A load, 230VAC
C6 & Hybrid mode ready!
REVOLUTION87 provides tight DC regulation to 
support C6 mode and Hybrid graphic power saving 
mode thanks to its ZERO LOAD (0W) Design.
1-130W
C6 state CPU
1-300W
Hybrid mode GPU
With 1W power consumption (C6 state / hybrid mode), most PSUs 
would have difficulties to maintain stable voltage output, and might 
shut-down for protection, otherwise their unstable voltage could 
damage system components!
37
36
35
34
33
32
31
0                      15                    30                    45                      60
35
35.5
36
36
32
33
34
34.5
System 
Temperature
Time after system shut down 
o
C
Without
HeatGuard
With
HeatGuard
second