iStarUSA TC-1200PD1 Benutzerhandbuch
2.7 RISE TIME
20ms max at full load.
3.0 PROTECTION:
When OCP, OVP, UVP, OTP, OPP, or short protection is triggered, the main
outputs will be latched off. The main outputs can be reset by cycling the DC
remote on/off or AC power. +5Vsb output is auto recovery when fault condition
removed.
3.1 OVER CURRENT PROTECTION
+12V1 & +12V2
22A~35A
+12V3 & +12V4
39A~55A
+5V 33A~50A
+3.3V 33A~50A
3.2 OVER VOLTAGE PROTECTION
+3.3V output
4.5 Vmax.
+5.0V output
7.0 Vmax.
+12.0V output 15.6 Vmax.
3.3 SHORT PROTECTION
All output to GND.
3.4 UNDER VOLTAGE PROTECTION
+3.3V output
2.0 Vmin.
+5.0V output
3.3 Vmin.
+12.0V output 8.5 Vmin.
4.0 ENVIRONMENT:
4.1 OPERATING TEMP. 10
o
C to +50
o
C
4.2 STORAGE TEMP. -20
o
C to +70
o
C
4.3 OPERATING HUMIDITY 20% to 90%, non-condensing
4.4 STORAGE HUMIDITY 5% to 95%, non-condensing
4.5 OPERATING ALTITUDE
0 to 10,000 feet
4.6 STORAGE ALTITUDE
0 to 50,000 feet