iStarUSA TC-1200PD1 Benutzerhandbuch

Seite von 7
2.7 RISE TIME
20ms max at full load. 
3.0 PROTECTION:
When OCP, OVP, UVP, OTP, OPP, or short protection is triggered, the main 
outputs will be latched off. The main outputs can be reset by cycling the DC 
remote on/off or AC power. +5Vsb output is auto recovery when fault condition 
removed. 
3.1 OVER CURRENT PROTECTION
+12V1 & +12V2 
22A~35A 
+12V3 & +12V4 
39A~55A 
+5V 33A~50A 
+3.3V 33A~50A 
3.2 OVER VOLTAGE PROTECTION
+3.3V output 
4.5 Vmax. 
+5.0V output 
7.0 Vmax. 
+12.0V output  15.6 Vmax. 
3.3 SHORT PROTECTION
All output to GND. 
3.4 UNDER VOLTAGE PROTECTION
+3.3V output 
2.0 Vmin. 
+5.0V output 
3.3 Vmin. 
+12.0V output  8.5 Vmin. 
4.0 ENVIRONMENT: 
4.1 OPERATING TEMP.            10 
o
C to +50 
o
C
4.2 STORAGE TEMP.             -20 
o
C to +70 
o
C
4.3 OPERATING HUMIDITY    20% to 90%, non-condensing
4.4 STORAGE HUMIDITY       5% to 95%, non-condensing
4.5 OPERATING ALTITUDE 
0 to 10,000 feet
4.6 STORAGE ALTITUDE   
0 to 50,000 feet