EN55022/EN55024
Harmonics IEC61000-3-2
Class
D
Flicker IEC61000-3-3
ESD
Susceptibility
Susceptibility
EN-61000-4-2
8KV by Air, 4KV by Contact
Performance Criteria B
Radiated
Susceptibility
Susceptibility
EN61000-4-3
80MHz~1000MHz
(3V/m(mns) Amplitude 80% AM 1KHz
Criteria A
(3V/m(mns) Amplitude 80% AM 1KHz
Criteria A
EFT/Burst
EN61000-4-4
5KHz, AC: 1KV, DC: 0,5 KV, Performance Criteria B
Surge
Voltage
Voltage
EN61000-4-5
Line-to-Line: 1KV
Line-to-Ground: 2KV
Performance Criteria B
Line-to-Ground: 2KV
Performance Criteria B
Conducted
Susceptibility
Susceptibility
EN61000-4-6
0.15MHz~80MHz
3V/m Amplitude 80% AM 1KHz
Performance Criteria A
3V/m Amplitude 80% AM 1KHz
Performance Criteria A
RF
Conducted
Conducted
EN61000-4-8
50 Hz/3A(ms)/m Performance Criteria A
Voltage Dips
and
Interruptions
and
Interruptions
EN61000-4-11
30%(Voltage Dips)
60%(Voltage Dips)
>95%(Voltage Dips)
60%(Voltage Dips)
>95%(Voltage Dips)
10 ms
100ms
500ms
500ms
Criteria B
Criteria C
Criteria C
Leakage
Current
Current
EN60950-1 1.0mA@240VAC
!
5.7 Safety
Agency
Requirements
This power supply is designed to meet the following safety
Table 13: Product Safety
Product Safety:
UL,cUL UL60950-1
CB IEC60950-1
TUV EN60950-1
CCC
6 Reliability
6.1 Mean Time Between Failures (MTBF)
The MTBF of the power supply shall be calculated utilizing the Part-Stress Analysis method of MIL217F.
The calculated MTBF of the power supply shall be greater than 100,000 hours under the following
The calculated MTBF of the power supply shall be greater than 100,000 hours under the following
conditions:
Full rated load; 120V AC input; Ground Benign; 25°C
Full rated load; 120V AC input; Ground Benign; 25°C
!
7. Mechanical Overview
Dimension: 85.5(W) x 84mm(H) x 285mm(D)