Intel R1304BTLSHBN8 Benutzerhandbuch

Seite von 67
Peripheral and Hard Drive Support 
Intel
®
 Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS 
28 
Revision 2.1 
Intel order number G17455-005 
 
 
Slimline optical drive bay 
Hot-swap Drive Bays 
Figure 15. Intel
®
 Server Systems R1304BTLSHBN Drive Bays 
6.1  Optical Drive Support  
Both the fixed and hot-swap systems provide a slimline drive bay that you can configure for an 
SATA optical CD-ROM or DVD/CDR drive. The slimline devices are not hot-swappable. 
6.1.1 
Optical Drive Support 
The server systems support a slimline SATA optical drive.  
6.2  Hard Disk Drive Support 
The Intel
®
 Server System R1304BTSSFAN/R1304BTLSFAN supports up to four, 3.5-inch by 1-
inch fixed SATA hard disk drives. The drives are mounted inside the chassis and are not hot-
swappable. The Intel
®
 Server System R1304BTLSHBN supports up to four SATA hard disk 
drives mounted in hot-swappable drive carriers. 
6.2.1 
System Fan Connectors 
The Intel
®
 Server Systems R1304BTSSFAN, R1304BTLSFAN, and R1304BTLSHBN support 
three system cooling fans. The following table provides the pin-out for each connector. 
Table 25. System Four-pin Fan Headers Pin-outs 
Pin 
Signal Name 
Type 
Description 
Ground 
Power 
GROUND is the power supply ground. 
Fan Power 
Power 
Fan Power 
Fan Tach 
Out 
FAN_TACH signal is connected to the Heceta* to monitor the FAN 
speed. 
PWM 
Control 
Pulse Width Modulation 
– Fan Speed Control signal