Adtran XFP 10G 1550nm 1442980G1C Merkblatt
Produktcode
1442980G1C
C A U T I O N
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
For more information, refer to the Installation and Maintenance Practice (P/N 61442980G1C-5)
Warranty
: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at
©2009 ADTRAN, Inc. All Rights Reserved.
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
*61442980G1C-22A*
C
OMPLIANCE
CAUTION
!
♦
Electrostatic Discharge (ESD) can damage electronic modules.
When handling modules, wear an antistatic discharge wrist
strap to prevent damage to electronic components. Place
modules in antistatic packing material when transporting or
storing. When working on modules, always place them on an
approved antistatic mat that is electrically grounded.
strap to prevent damage to electronic components. Place
modules in antistatic packing material when transporting or
storing. When working on modules, always place them on an
approved antistatic mat that is electrically grounded.
♦
The XFP meets or exceeds all the applicable requirements of
NEBS, Telcordia GR‐63‐CORE, and GR‐1089‐CORE. The XFP
is intended for deployment in Central Office type facilities,
EEEs, EECs, and locations where the NEC applies (for
example, Customer Premises). The XFP is to be installed in
ADTRAN products in Restricted Access Locations only, and
installed by trained service personnel.
NEBS, Telcordia GR‐63‐CORE, and GR‐1089‐CORE. The XFP
is intended for deployment in Central Office type facilities,
EEEs, EECs, and locations where the NEC applies (for
example, Customer Premises). The XFP is to be installed in
ADTRAN products in Restricted Access Locations only, and
installed by trained service personnel.
This device complies with FCC 47 CFR Part 15, Class B. Operation
is subject to the following two conditions:
is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN
could void the userʹs authority to operate this equipment.
could void the userʹs authority to operate this equipment.
♦
Per GR‐1089‐CORE, the ADTRAN system in which the SFP is
being deployed is designed and intended for installation as
part of a Common Bonding Network (CBN). The ADTRAN
system in which the SFP is being deployed is not designed nor
intended for installation as part of an Isolated Bonding
Network (IBN).
being deployed is designed and intended for installation as
part of a Common Bonding Network (CBN). The ADTRAN
system in which the SFP is being deployed is not designed nor
intended for installation as part of an Isolated Bonding
Network (IBN).
♦
Per GR‐1089‐CORE Section 9, the XFP does not have an
internal DC connection between battery return and frame
ground. The XFP can be installed in a DC‐I (isolated) or DC‐C
(common) installation. For installations where other cards or
the host system have internal connections between battery
return and frame ground, the system would be intended for
deployment only in a DC‐C installation.
ground. The XFP can be installed in a DC‐I (isolated) or DC‐C
(common) installation. For installations where other cards or
the host system have internal connections between battery
return and frame ground, the system would be intended for
deployment only in a DC‐C installation.
♦
The ADTRAN system chassis frame ground terminal must be
connected to a reliable earth ground to ensure that the metal
enclosure of the XFP is properly grounded via the backplane
connector.
connected to a reliable earth ground to ensure that the metal
enclosure of the XFP is properly grounded via the backplane
connector.
CAUTION
C
The XFP is a Class 1 Laser Product and complies with the Laser
Safety requirements of FDA 21CFR 1040.10 and 1040.11, and
EN60825‐1 and ‐2. The XFP is NRTL listed and CB Certified to all
applicable American and European safety standards.
For continued compliance with the above laser safety standards,
only approved Class 1 modules from our approved vendor list,
located on the ADTRAN website, should be installed in ADTRAN
products.
Safety requirements of FDA 21CFR 1040.10 and 1040.11, and
EN60825‐1 and ‐2. The XFP is NRTL listed and CB Certified to all
applicable American and European safety standards.
For continued compliance with the above laser safety standards,
only approved Class 1 modules from our approved vendor list,
located on the ADTRAN website, should be installed in ADTRAN
products.
NOTE
The Gigabit Ethernet port(s) are optical and therefore are not
classified as any type of port as defined in Appendix B of GR‐
1089‐CORE Issue 4.
classified as any type of port as defined in Appendix B of GR‐
1089‐CORE Issue 4.
The XFP is designed to meet the following environmental classes:
♦
ETSI EN 300 019‐1‐1 “Classification of environmental
conditions; Storage,” Class 1.2
conditions; Storage,” Class 1.2
♦
ETSI EN 300 019‐1‐2 “Classification of environmental
conditions, Transportation,” Class 2.3
conditions, Transportation,” Class 2.3
♦
ETSI EN 300 019‐1‐3 “Classification of environmental
conditions, Stationary use at weather‐protected locations,”
Class 3.3
conditions, Stationary use at weather‐protected locations,”
Class 3.3
The equipment is designed to function without degradation
during exposure to all test severities per Class 3.3.
during exposure to all test severities per Class 3.3.