Intel SR1630BC SR1630BCNA Benutzerhandbuch

Produktcode
SR1630BCNA
Seite von 58
Appendix A: Integration and Usage Tips 
Intel® Server System SR1630BC TPS 
Revision 1.5 
Intel order number E44588-005 
 
 
39
 
Appendix A: Integration and Usage Tips 
This section provides a list of useful information unique to the Intel
®
 Server System SR1630BC 
that you should keep in mind while integrating the server system. 
• 
The Intel
®
 Server System SR1630BC requires the use of a shielded LAN cable to 
comply with Immunity regulatory requirements.  
• 
Intel
®
 Remote Management Module 3 is not supported the Intel
®
 Server System 
SR1630BC because of mechanical issue.  
• 
Management feature is not support on the power supply of Intel
®
 Server System 
SR1630BC.  
• 
The Intel
®
 Server system SR1630BC supports one riser card that supports one low-
profile half-length PCI Express* x8 add-in card which consumes power less than 15 W. 
• 
Processor fans are not needed and are not supported. The system fan module provides 
the necessary cooling needed for the system.  
• 
You must use the system air duct to maintain system thermals. 
• 
System fans are not hot-swappable. 
• 
A screw on the front edge of the top cover is required when the unit is installed in a user-
accessible environment.  
• 
The FRUSDR utility must be run to load the proper sensor data records for the server 
chassis onto the server board. 
• 
Make sure the latest system software is loaded. This includes the system BMC firmware, 
FRUSDR, and BIOS. You can download the latest system software from: 
http://support.intel.com/support/motherboards/server/S5500BC/